Lenovo (ThinkPad) ThinkPad L380
Lenovo ThinkPad L380 System Firmware R0RET54W, version 1.37
Atom Feed
Version 0.1.37
2024-07-05 10:59:23
Modified ME OEM_ESRT_INTEL_ME_FW_CORPORATE_GUID for ME device firmware GUID conflict issue.
Urgency | high |
---|---|
Reported Success | 100% (low confidence) |
Licenses | |
Security |
|
Tested By |
The vendors testing the update provide no warranty of any kind (express or implied), including but not limited to the warranties of merchantability, fitness for a particular purpose or non-infringement. In no event shall these vendors be liable for any claim, damages or other liability. |
Release Gating |
|
Version 0.1.36
2024-05-09 11:05:19
-Removal of confusing help message for WOL -Fix image processing vulnerabilities -Updated TpmFwCapsule package -Updated BIOS Guard module.-Fixed Various vulnerabilities in NetworkPkg IP stack implementation.-Dbx update for blackLotus vulnerability -Updated build ID and version to ver.1.53
Urgency | high |
---|---|
Reported Success | 100% (low confidence) |
Licenses | |
Security |
|
Tested By |
The vendors testing the update provide no warranty of any kind (express or implied), including but not limited to the warranties of merchantability, fitness for a particular purpose or non-infringement. In no event shall these vendors be liable for any claim, damages or other liability. |
Release Gating |
|
Version 0.1.35
2024-01-15 09:01:02
New functions or enhancements: -UMRS07350 LogoFAIL Vulnerability
Urgency | high |
---|---|
Reported Success | 100% (medium confidence) |
Licenses | |
Security |
|
Release Gating |
|
Version 0.1.34
— not be suitable for production systems
2023-09-15 07:37:42
New functions or enhancements: -Update LBVT tool to 2023.07.18.0 -Fixed PCR bank selection and HashLib capability are not synchronized -Version 04.31.000 code of FIT's InROM diagnostics
Urgency | high |
---|---|
Licenses | |
Security |
|
Release Gating |
|
Version 0.1.33
2023-08-02 09:28:31
New functions or enhancements:
-Update Version 04.30.000 code of FIT's InROM diagnostics.
-Update LBVT tool to 2020.03.23.0 to fix build error
-Fixed Heap buffer overflow issues in Tcg2MeasurePeImage() and Tcg2MeasureGptTable()
Urgency | high |
---|---|
Reported Success | 100% (medium confidence) |
Licenses | |
Security |
|
Release Gating |
|
Version 0.1.32
2023-02-03 03:27:17
New functions or enhancements:-Update Version 04.27.000 code of FIT's InROM diagnostics.
Urgency | high |
---|---|
Reported Success | 96% (medium confidence) |
Licenses | |
Security |
|
Release Gating |
|
Version 0.1.31
2022-12-26 10:42:26
New functions or enhancements: -W/A for MEFW Capsule Update.-Update Version 04.26.000 code of FIT's InROM diagnostics.
Urgency | high |
---|---|
Reported Success | 100% (low confidence) |
Licenses | |
Security |
|
Release Gating |
|
Version 0.1.29
2022-09-01 07:22:05
New functions or enhancements: - Updated the CPU microcode.- Updated Version 04.24.000 code of FIT's InROM diagnostics.- Updated GUID for ME device firmware.- Updated MEBx 11.0.0.0012.
Urgency | high |
---|---|
Reported Success | 100% (low confidence) |
Licenses | |
Security |
|
Release Gating |
|