BusLogic
BT-646 image
Update PROM for the
646
Storage Dimensions
Term Power Fuse
SDC Drivers
OS/2 v.3 Switches
BT-646S/D SCSI Adapter for MicroChannel Systems
32-bit bus master DMA transfers of up to 40MB/second across
the MC bus, up to 10 MB/sec synchronous and up to 7 MB/set asynchronous
SCSI data transfers. Support for up to seven SCSI devices, hard drives
with up to 8GB capacity each. Enhanced SCSI-2 features: scatter-gather,
disconnect-reconnect, and command-tag queuing
BT-646x Host Interface Microprocessor
A 20MHz Intel 80186 16-bit MPU is used to supply the speed
for low command overhead. This MPU coordinates all activity on the BT-646S/D
under the direction of the board�s firmware, including initialization,
command decoding, interrupt generation, and control of the data flow among
the board�s components.
Differences between and 646S and BT-646D
BT-646S Single-ended active termination ,
BT-646D Differential termination
Multitasking Operation
For operating systems such as UNIX, NetWare, and OS/2,
the mailbox protocol of the BT-64x provides true multitasking operation.
Through the use of a mailbox structure, the BT-64x can support up to 255
tasks with minimum host processor intervention. Onboard firmware controls
all of the SCSI activity that a task requires, including the Arbitration,
Selection, Disconnection, Reconnection, and command completion status.
This same mailbox protocol supports both initiator and target mode operation
permitting high speed host-to-host communication and scatter-gather data
transfers.
Disk Drive Power Connector
A 4-pin disk drive power connector (J4) is located at
the top edge of the BT-64x board next to the SCSI connector Jl. This connector
provides +12V and +5V power.
Note: The BT-64x brings
the 12 volt power supply to the 4-pin power connector (14) via three gold
fingers on the edge connector. The power rating of the Micro Channel edge
connector on the12 volt is one ampere per finger. Consequently, fhe maximum
power allowed from the 12 volts (Pin 1 of J4) is three amperes. Because
certain large SCSI drives may require more than three amperes when their
motors are spinning up, BusLogic recommends that this connector not be
connected to these large SCSI drives.
Based on the power rating of the SCSI drives, if is generally
recommended that
this power connector not be daisy chained to multiple drives.
Disk > 1 GB and not SC0 UNIX.
In the DOS environment, INT 13 calls are routed
through the BT-64xA/S/D�s ROM BIOS. This on-board BIOS intercepts host
interrupt 13H calls and dispatches a command to the BT-64x for all host
to SCSI disk accesses. When the >lGB option is turned on, the BT-640A BIOS
can access up to 8 GBytes per disk. Otherwise, it can only access the first
1 GBytes even if the formatted disk capacity is greater than 1GByte. This
1GByte restriction does not apply to other operating systems, such as NetWare,
UNIX, SC0 UNIX 3.2.4, or OS/2 if the operating system can boot without
accessing > 1 GBytes. If the operating system�s bootable image resides
below 1 GBytes then it can boot via Interrupt 13H. Once any of these operating
systems are booted, the disk accesses are not routed through Interrupt
13H and the operating system can access the entire disk space even if the
> 1 GB option is not turned on.
Under SC0 UNIX 3.2.2, the >lGB option must be turned off
because the operating system itself has a 1 GByte limitation. Otherwise,
disk images may be corrupted when the 1 GByte boundary is reached. For
SC0 UNIX 3.2.4, the operating system does not impose the 1 GByte limit,
and this
option can be turned on or off accordingly. Consequently, the >lGByte
support must be turned on under the following two conditions: (1) the combined
space of all the DOS partitions exceeds
lGByte, or (2) >lGByte disk accesses are required to boot the operating
system. To enable the > 1 GB support, turn on this option. Note:
If this option is changed, you must reformat the disk to avoid corrupting
the existing file system.
BT-640A SCSI Adapter for MicroChannel Systems
Host Bus: 16 and 32-bit MCA 32-bit busmaster DMA
transfers of up to 40 MB/sec
MPU: 8 MHz 80188 onboard microprocessor
SCSI Controller: NCR 53C94
ASIC: 86C05 busmaster ASIC
SCSI Bus: Up to 7 devices
SCSI-2
command set compatible
Up to
5MB/sec synchronous or asynchronous
Onboard termination: single-ended 3 resistor packs (220/330
ohm)Term power supplied to bus
Firmware: Mailbox structure supports multitasking and scatter/gather
BIOS: Supports hard drive boot Up to 8GB storage capacity supported
in BIOS
LED Operation
When power is first applied to the BT-640A, an on-board
diagnostic routine is run to verify that the major functional components
of the board are operating correctly. The bus master chip, the SCSI controller
chip, the firmware PROM, the local RAM and internal data buses are tested.
Results of the tests are indicated by an LED on the board.
The LED will first turn on when power is applied. If the
diagnostics find no malfunctions, the LED will then go off. In normal operation,
the LED will be illuminated when command or SCSI bus activity occurs on
the board. If an error is detected by the diagnostics, the LED will repeatedly
flash a specific number of times, with a long pause between flashes, to
indicate the board function which failed. This will continue until the
board is powered down or reset. Failure interpretation from the number
of flashes is as follows:
Flashes
|
640A-646S/D Failure
|
Always On
|
Not operating/missing terminator |
1
|
Firmware ROM checksum failure |
2
|
Local RAM test failure |
3
|
SCSI controller / interface failure |
4
|
Internal data bus failure |
5
|
Internal address bus failure |
6
|
Bus master chip failure |
7
|
SCSI drive type mismatch* |
Constant
|
Fuse Blown. |
�This error is applicable to the BT-646 when single-ended SCSI drivers
are connected to the differential SCSI bus.
BT640 and SDC3211B 32 Bit SCSI-1
BT-640A single-ended termination
RP1, RP2 and RP3 are 8-pin 220/330 ohm SIP resistor packs (221/331G
or equivalent)
Update PROM for the
640
NOTE - To use the ROM files to
update your BusLogic SCSI host adapter you must have a EPROM burner.
BusLogic will in no way provide any support on how to get your EPROM burner
to work or anything else in the EPROM burning process.
640a-335.zip
ROM Binaries for BT-640A: 3.35-4.70
BT646 S/D and SDC3211F 32-Bit Fast SCSI-2
BT-646S has RP2 and RP3 only. single-ended
termination
RP2 and 3 are 10-pin 100 ohm SIPs containing 9 bused 100 ohm resistors
(CTS 4610X-1-101)
BT-646D has RP6-RP13 differential
termination
RP6, 8, 10 and 12 are 10-pin SIPs containing 5 isolated 150 ohm resistors
(Bourns 4610X-2-151)
RP7, 9, 11 and 13 are 10-pin SIPs containing 9 bused 330 ohm esistors.(Bourns
4610X-1-331)
Update PROM for the
646 S/D
NOTE - You must have a EPROM burner.
BusLogic will NOT help with burning.
It's up to YOU.
646s-336.zip
ROM Binaries for BT-646S: 3.36-4.70
MULTIMASTER:
Drivers / Configuration Files for MultiMaster SCSI Host Bus
Adapters
adf-150.exe
Config file for BT-640/646 v1.50 (3-8-93)
dosaspi.exe
DOS/Win SCSI ASPI Drivers v4.31C (7-12-96)
mmodt.exe
SCO Unix ODT / OpenServer 2.x/3.x v4.01 (8-26-97)
mmunix.exe
SCO Unix OpenServer 5.0.x v4.01 (7-21-97) & Unixware 2.x v3.02 (7-24-97)
nextstep.exe
NeXTStep 486 v3.2 SCSI Driver (10-3-94)
ntaspi.exe
NT ASPI Driver
nw31x.exe
NetWare 3.1X SCSI Drivers v2.56 (7-3-96)
nw4x.exe
NetWare 4.X SCSI Drivers v1.56 (7-3-96)
nwgam.exe
Netware HAM drive w/GAM spt v5.02 (7-11-97)
nwham.exe
Netware standard HAM driver v5.02 (5-30-97)
os2-2x.exe
OS/2 v2.XX SCSI Driver v1.54 (10-23-96)
warp.exe
OS/2 3.x/4.0 (Warp)Driver v1.54 (10-23-96)
win95.exe
Win95 driver upgrade v5.02 (7-14-97)
winnt-a.exe
WinNT 3.5x driver for Alpha v5.02 (7-17-97)
winnt.exe
WinNT 3.5x/4.0 SCSI driver v5.02 (7-14-97)
Storage Dimensions
SDC1611; 16-Bit SCSI-1 Micro Channel Host Bus Adapter
SDC3211B;
32-Bit SCSI-1 Micro Channel Host Bus Adapter
SDC3211F;
32-Bit Fast SCSI-2 Micro Channel Host Bus Adapter
LANStor MCA RAIDCard; 32-Bit MCA F/W SCSI-2 RAID Controller
Term Power Fuse
SDCxx11x and BT-64x use a Microlite Little Fuse that is
125v and 1/2 amps (Littel 27301.5 125V 1.5A or equivalent micro fuse).
It is difficult to see that the fuse is blown so you will need to use a
VOM to test for continuity. The fuse can blow if termination power settings
are not correct on the SCSI devices or if you disconnect the SCSI cables
while the card or SCSI devices have power. (Ed.
Sure ain't kidding!)
SDC Drivers
CONFG243.EXE
- (111k) .adf files for all Storage Dimensions SCSI adapters.
Buslogic drivers are the same... The Readme
file
Micro
Channel RAIDCard - v2.0 (269K) all the required files to support
the -002 Micro Channel RAIDCard for OS/2 and NetWare. For use under NetWare,
you must also have the LANStor
Plus software. When unarchiving this file, use the "-D" option
to restore the directory structure.
LANStor5
- v6.10 (109k) SCSI NLM for NetWare v3.11 - supports the SDC1611/3211x
under NetWare versions 3.11. Not tested or certified using NetWare v3.12
or v4.xx.
LANStor
Plus - v2.50 (114k) SCSI NLM for NetWare v3.12 and v4.xx
most current version of LANStor for the SDC1611/3211x, and the SDC3231WS
SCSI Adapters. It includes LAPIS Plus which which is Artecon' ASPI
layer (manager).
OS/2
Switches
This adapter driver supports all bus master type BusLogic SCSI Host
Adapter products. The BTSCSI.ADD device driver supports the following BusLogic
host adapters:
o BT-640A, BT-646S - Micro Channel SCSI Host Adapters
Usually, ADD device drivers determine the parameters automatically.
The following parameters are provided in case it is necessary to override
the default parameter selection.
BASEDEV= -- BTSCSI.ADD ------------------------------------------
+- /V -+ Verbose mode
----------------------------------------------------------------|
+- /A:n ------------------------+
Adapter number
|- /!DM -------------| Disable DASD
Manager
| +- :unitlist
-| List of unit IDs
|- /!SM -------------| Disable
SCSI Manager
| +- :unitlist
-| List of unit IDs
|- /TQ ----------------|
| +- :unitlist
-|
|- /BON:n -------------|
+- /BOFF:n ------------+
SCSI
Controllers
9595
Main Page
|