Supermicro AS-1115SV-WTNRT SPECpower_ssj2008 = 22,287 overall ssj_ops/watt
Test Sponsor: Supermicro SPEC License #: 1176 Test Method: Single Node
Tested By: Supermicro Test Location: San Jose, CA, USA Test Date: Aug 17, 2023
Hardware Availability: Sep-2023 Software Availability: Apr-2023 Publication: Sep 19, 2023
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.1% 7,028,923 236 29,775
90% 90.0% 6,380,926 222 28,718
80% 80.0% 5,674,578 208 27,252
70% 70.1% 4,969,662 191 26,058
60% 60.0% 4,253,382 163 26,015
50% 50.1% 3,555,012 152 23,338
40% 40.1% 2,841,128 142 19,966
30% 30.0% 2,126,993 132 16,171
20% 20.0% 1,418,674 120 11,802
10% 10.0% 709,112 106 6,672
Active Idle 0 74.7 0
∑ssj_ops / ∑power = 22,287
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: Supermicro
Model: AS-1115SV-WTNRT
Form Factor: 1U
CPU Name: AMD EPYC 8534P
CPU Characteristics: 64-Core, 2.3 GHz, 128MB L3 Cache
CPU Frequency (MHz): 2300
CPU(s) Enabled: 64 cores, 1 chip, 64 cores/chip
Hardware Threads: 128 (2 / core)
CPU(s) Orderable: 1 chip
Primary Cache: 2 MB I + 2 MB D on chip per core
Secondary Cache: 64 MB I+D on chip per core
Tertiary Cache: 128 MB I+D on chip per chip,
Other Cache: None
Memory Amount (GB): 96
# and size of DIMM: 6 x 16 GB
Memory Details: 6 x 16GB 1Rx8 PC5-4800B; CPU1 A1,B1,C1,D1,E1,F1 populated.
Power Supply Quantity and Rating (W): 1 x 860
Power Supply Details: PWS-861A-1R
Disk Drive: 1 x 1TB Samsung SSD 980 PRO
Disk Controller: Embedded SATA Controller
# and type of Network Interface Cards (NICs) Installed: 1 x Dual LAN BCM 57416 10GbE BaseT Ethernet Controller
NICs Enabled in Firmware / OS / Connected: 2/2/1
Network Speed (Mbit): 10000
Keyboard: None
Mouse: None
Monitor: None
Optical Drives: No
Other Hardware: None
Software
Power Management: Enabled (see SUT Notes)
Operating System (OS): Microsoft Windows Server 2022 Datacenter
OS Version: Version 21H2 (OS Build 20348.1668)
Filesystem: NTFS
JVM Vendor: Oracle Corporation
JVM Version: Java HotSpot(TM) 64-Bit Server VM (build 17.0.1+12-LTS-39, mixed mode, sharing)
JVM Command-line Options: -server -Xms2048m -Xmx2048m -Xmn1900m -XX:+UseParallelGC -XX:ParallelGCThreads=4 -XX:+UseLargePages -XX:LargePageSizeInBytes=2m -XX:+UseBiasedLocking -XX:InlineSmallCode=1500 -XX:UseAVX=1 -XX:AutoBoxCacheMax=20000 -XX:+OptimizeFill -XX:+AggressiveHeap
JVM Affinity: start/NODE[0, 1] /AFFINITY [ [0xF, 0xF0, 0xF00, 0xF000, 0xF0000, 0xF00000, 0xF000000, 0xF0000000, 0xF00000000, 0xF000000000, 0xF0000000000, 0xF00000000000, 0xF000000000000, 0xF0000000000000, 0xF00000000000000, 0xF000000000000000 ]
JVM Instances: 32
JVM Initial Heap (MB): 2048
JVM Maximum Heap (MB): 2048
JVM Address Bits: 64
Boot Firmware Version: 1.0
Management Firmware Version: 01.01.01
Workload Version: SSJ 1.2.10
Director Location: Controller
Other Software: KB5025230
Boot Firmware Settings
Management Firmware Settings
Fan Mode: Standard Speed
System Under Test Notes
Controller System
Hardware
Hardware Vendor: HP
Model: HP EliteBook 745 G6
CPU Description: AMD Ryzen 7 PRO 3700U
Memory amount (GB): 32
Software
Operating System (OS): Microsoft Windows Server 2019 Standard
JVM Vendor: OpenJDK
JVM Version: OpenJDK 64-Bit Server VM 18.9 (build 11.0.2+9, mixed mode)
CCS Version: 1.2.6
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: YOKOGAWA, Inc.
Model: WT310E
Serial Number: C2XM03068V
Connectivity: USB2
Input Connection: Default
Metrology Institute: TESCOM
Accredited by: 12-May-2023
Calibration Label: T114528
Date of Calibration: 12-May-2023
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.10.0-82175bac-20220817
Setup Description: Connected to PSU 1
Temperature Sensor temp1
Hardware Vendor: iButtonLink, Inc.
Model: LinkUSBi + T-Probe
Driver Version: FTDI USB Serial Device 1.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 50 mm in front of SUT main intake
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 236 29.4
90% 222 29.7
80% 208 29.9
70% 191 30.0
60% 163 29.9
50% 152 29.8
40% 142 29.6
30% 132 29.3
20% 120 29.1
10% 106 28.8
Active Idle 74.7 28.5
Line Standard Minimum Temperature (°C) Elevation (m)
220V / 60 Hz / 1 phase / 2 wires 28.5 132
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     7,205,500
Calibration 2     7,112,157
Calibration 3     7,073,913
ssj_ops@calibrated=7,093,035
100% 99.1% 7,093,035 7,028,923
90% 90.0% 6,383,731 6,380,926
80% 80.0% 5,674,428 5,674,578
70% 70.1% 4,965,124 4,969,662
60% 60.0% 4,255,821 4,253,382
50% 50.1% 3,546,517 3,555,012
40% 40.1% 2,837,214 2,841,128
30% 30.0% 2,127,910 2,126,993
20% 20.0% 1,418,607 1,418,674
10% 10.0% 709,303 709,112
Active Idle   0 0
Graph of results