New H3C Technologies Co., Ltd. H3C UniServer R4700 G5 | SPECpower_ssj2008 = 10,628 overall ssj_ops/watt | ||||
Test Sponsor: | New H3C Technologies Co., Ltd. | SPEC License #: | 9066 | Test Method: | Single Node |
Tested By: | New H3C Technologies Co., Ltd. | Test Location: | Hangzhou, Zhejiang, China | Test Date: | May 7, 2023 |
Hardware Availability: | Mar-2023 | Software Availability: | Jan-2023 | Publication: | May 24, 2023 |
System Source: | Single Supplier | System Designation: | Server | Power Provisioning: | Line-powered |
Performance | Power | Performance to Power Ratio | ||
---|---|---|---|---|
Target Load | Actual Load | ssj_ops | Average Active Power (W) | |
100% | 99.9% | 6,774,516 | 653 | 10,380 |
90% | 90.4% | 6,130,402 | 498 | 12,302 |
80% | 80.1% | 5,436,792 | 390 | 13,937 |
70% | 69.7% | 4,728,206 | 342 | 13,835 |
60% | 59.9% | 4,066,197 | 309 | 13,173 |
50% | 50.0% | 3,391,326 | 282 | 12,038 |
40% | 40.1% | 2,718,725 | 259 | 10,491 |
30% | 30.0% | 2,035,140 | 238 | 8,534 |
20% | 20.0% | 1,357,926 | 216 | 6,278 |
10% | 10.0% | 679,259 | 191 | 3,548 |
Active Idle | 0 | 133 | 0 | |
∑ssj_ops / ∑power = | 10,628 |
Set Identifier: | sut |
Set Description: | System Under Test |
# of Identical Nodes: | 1 |
Comment: | None |
Hardware | |
---|---|
Hardware Vendor: | New H3C Technologies Co., Ltd. |
Model: | H3C UniServer R4700 G5 |
Form Factor: | 1U |
CPU Name: | Intel Xeon Platinum 8360Y |
CPU Characteristics: | 36-Core, 2.40GHz, 54MB L3 Cache |
CPU Frequency (MHz): | 2400 |
CPU(s) Enabled: | 72 cores, 2 chips, 36 cores/chip |
Hardware Threads: | 144 (2 / core) |
CPU(s) Orderable: | 1,2 chips |
Primary Cache: | 32 KB I + 48 KB D on chip per core |
Secondary Cache: | 1280 KB I+D on chip per core |
Tertiary Cache: | 54 MB I+D on chip per chip |
Other Cache: | None |
Memory Amount (GB): | 512 |
# and size of DIMM: | 16 x 32 GB |
Memory Details: | 16 x 32GB 2Rx8 PC4-3200AA-RE4 Samsung; slot DIMM000, DIMM010, DIMM020, DIMM030, DIMM040, DIMM050, DIMM060, DIMM070, DIMM100, DIMM110, DIMM120, DIMM130, DIMM140, DIMM150, DIMM160, DIMM170 populated |
Power Supply Quantity and Rating (W): | 1 x 1300 |
Power Supply Details: | H3C GW-CRPS1300D3 |
Disk Drive: | 1 x Intel M.2 SSD 240GB SSDSCKKB240GZ |
Disk Controller: | Integrated SATA controller |
# and type of Network Interface Cards (NICs) Installed: | 1 x Quad-port Intel I350 Gigabit Ethernet controller |
NICs Enabled in Firmware / OS / Connected: | 4/1/1 |
Network Speed (Mbit): | 1000 |
Keyboard: | None |
Mouse: | None |
Monitor: | None |
Optical Drives: | No |
Other Hardware: | None |
Software | |
---|---|
Power Management: | Enabled (see SUT Notes) |
Operating System (OS): | Microsoft Windows Server 2019 Datacenter |
OS Version: | Version 1809(OS Build 17663.1) |
Filesystem: | NTFS |
JVM Vendor: | Oracle Corporation |
JVM Version: | Java HotSpot(TM) 64-Bit Server VM 18.9 (build 11.0.18+9-LTS-195, mixed mode) |
JVM Command-line Options: | -server -Xmn1825m -Xms1995m -Xmx1995m -XX:SurvivorRatio=1 -XX:TargetSurvivorRatio=99 -XX:ParallelGCThreads=2 -XX:AllocatePrefetchDistance=256 -XX:AllocatePrefetchLines=4 -XX:LoopUnrollLimit=45 -XX:InitialTenuringThreshold=12 -XX:MaxTenuringThreshold=15 -XX:InlineSmallCode=3900 -XX:MaxInlineSize=270 -XX:FreqInlineSize=2500 -XX:+UseLargePages -XX:+UseParallelOldGC -XX:UseAVX=0 -XX:-UseAdaptiveSizePolicy -XX:-ThreadLocalHandshakes |
JVM Affinity: | start /NODE[0-3] /AFFINITY [0x3,0xC,0x30,0xC0,0x300,0xC00,0x3000,0xC000,0x30000,0xC0000,0x300000,0xC00000,0x3000000,0xC000000,0x30000000,0xC0000000,0x300000000,0xC00000000] |
JVM Instances: | 72 |
JVM Initial Heap (MB): | 1995 |
JVM Maximum Heap (MB): | 1995 |
JVM Address Bits: | 64 |
Boot Firmware Version: | 5.58(C35) |
Management Firmware Version: | 3.35 |
Workload Version: | SSJ 1.2.10 |
Director Location: | Controller |
Other Software: | None |
Hardware | |
---|---|
Hardware Vendor: | New H3C Technologies Co., Ltd. |
Model: | H3C UniServer R4900 G3 |
CPU Description: | 6233 |
Memory amount (GB): | 64 |
Software | |
---|---|
Operating System (OS): | Windows Server 2008 R2 Enterprise Edition |
JVM Vendor: | Oracle Corporation |
JVM Version: | Java HotSpot(TM) 64-Bit Server VM 18.9 (build 11.0.18+9-LTS-195, mixed mode) |
CCS Version: | 1.2.6 |
Power Analyzer pwr1 | |
---|---|
Hardware Vendor: | CHROMA |
Model: | 66203 |
Serial Number: | 662030000500 |
Connectivity: | GPIB |
Input Connection: | Default |
Metrology Institute: | CNAS (China National Accreditation Service for Conformity Assessment) |
Accredited by: | CEPREI Calibration and Testing Center |
Calibration Label: | B210202003 |
Date of Calibration: | 23-Nov-2022 |
PTDaemon Host System: | same as CCS |
PTDaemon Host OS: | same as CCS |
PTDaemon Version: | 1.10.0-82175bac-20220817 |
Setup Description: | Connected to PSU |
Temperature Sensor temp1 | |
---|---|
Hardware Vendor: | DIGI. |
Model: | Watchport/H |
Driver Version: | 6.2.1.0 |
Connectivity: | USB |
PTDaemon Host System: | same as CCS |
PTDaemon Host OS: | same as CCS |
Setup Description: | Placed in front the main airflow inlet of the SUT less than 50mm |
Target Load | Average Active Power (W) | Minimum Ambient Temperature (°C) |
---|---|---|
100% | 653 | 24.7 |
90% | 498 | 24.6 |
80% | 390 | 24.6 |
70% | 342 | 24.4 |
60% | 309 | 24.2 |
50% | 282 | 24.1 |
40% | 259 | 24.0 |
30% | 238 | 23.9 |
20% | 216 | 23.9 |
10% | 191 | 23.8 |
Active Idle | 133 | 23.8 |
Line Standard | Minimum Temperature (°C) | Elevation (m) |
---|---|---|
235V / 50 Hz / 1 phase / 2 wires | 23.8 | 132 |
Target Load | Actual Load | ssj_ops | |
---|---|---|---|
Target | Actual | ||
Calibration 1 | 6,743,628 | ||
Calibration 2 | 6,777,456 | ||
Calibration 3 | 6,789,642 | ||
ssj_ops@calibrated=6,783,549 | |||
100% | 99.9% | 6,783,549 | 6,774,516 |
90% | 90.4% | 6,105,194 | 6,130,402 |
80% | 80.1% | 5,426,839 | 5,436,792 |
70% | 69.7% | 4,748,484 | 4,728,206 |
60% | 59.9% | 4,070,129 | 4,066,197 |
50% | 50.0% | 3,391,775 | 3,391,326 |
40% | 40.1% | 2,713,420 | 2,718,725 |
30% | 30.0% | 2,035,065 | 2,035,140 |
20% | 20.0% | 1,356,710 | 1,357,926 |
10% | 10.0% | 678,355 | 679,259 |
Active Idle | 0 | 0 |