SPECpower_ssj2008 Copyright (C) 2007-2022 Standard Performance Evaluation Corporation Fujitsu FUJITSU Server PRIMERGY TX1310 M5 (D3931-C100) SPECpower_ssj2008 = 9,993 overall ssj_ops/watt Test Sponsor: Fujitsu SPEC License #: 19 Tested By: Fujitsu Test Location: Kawasaki, Kanagawa, Japan Test Date: Dec 18, 2021 Publication: Jan 19, 2022 Hardware Availability: Mar-2022 Software Availability: Jun-2021 Test Method: Single Node System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered Benchmark Results Summary Performance | Power | Performance | | to Power | | Ratio Target Load | Actual Load | ssj_ops | Average | | | | Active Power | | | | (W) | ------------- | ------------- | ------------- | ------------- | ------------- 100% | 99.9% | 659,394 | 58.9 | 11,204 90% | 90.2% | 595,196 | 50.7 | 11,751 80% | 80.3% | 529,513 | 43.7 | 12,124 70% | 70.3% | 463,722 | 39.0 | 11,888 60% | 59.7% | 393,761 | 34.0 | 11,584 50% | 50.3% | 332,000 | 30.2 | 11,011 40% | 40.0% | 264,032 | 26.8 | 9,861 30% | 29.8% | 196,303 | 24.0 | 8,170 20% | 19.9% | 131,513 | 21.6 | 6,090 10% | 10.0% | 65,719 | 19.0 | 3,457 Active Idle | 0 | 15.6 | 0 sum of ssj_ops / sum of power = | 9,993 System Under Test Set: 'TX1310M5' Set Identifier: TX1310M5 Set Description: System Under Test # of Identical Nodes: 1 Comment: Single Node HARDWARE Hardware Vendor: Fujitsu Model: FUJITSU Server PRIMERGY TX1310 M5 (D3931-C100) Form Factor: Tower CPU Name: Intel Xeon E-2356G (Intel Turbo Boost Technology up to 5.0GHz) CPU Characteristics: 6-Core, 3.2GHz, 12MB L3 Cache CPU Frequency (MHz): 3200 CPU(s) Enabled: 6 cores, 1 chip, 6 cores/chip Hardware Threads: 12 (2 / core) CPU(s) Orderable: 1 chips Primary Cache: 32 KB I + 48 KB D on chip per core Secondary Cache: 512 KB I+D on chip per core Tertiary Cache: 12 MB I+D on chip per chip Other Cache: None Memory Amount (GB): 16 # and size of DIMM: 2 x 8196 MB Memory Details: 2 x 8 GB 1Rx8 PC4-3200AA-ED2-11; slots 1A, 1B populated Power Supply Quantity and Rating 1 x 250 (W): Power Supply Details: S26113-E591-V70-2 Disk Drive: 1 x SSD M.2 240GB, S26361-F5787-E240 Disk Controller: Integrated SATA Controller # and type of Network Interface 2 x Intel I210 Gigabit Network Connection Cards (NICs) Installed: (onboard) NICs Enabled in Firmware / OS / 2/2/1 Connected: Network Speed (Mbit): 1000 Keyboard: None Mouse: None Monitor: None Optical Drives: No Other Hardware: None SOFTWARE Power Management: Enabled (see SUT Notes) Operating System (OS): SUSE Linux Enterprise Server 15 SP3 OS Version: 5.3.18-57-default Filesystem: btrfs JVM Vendor: Oracle Corporation JVM Version: Oracle Java HotSpot(TM) 64-Bit Server VM 18.9 (build 11.0.9+7-LTS, mixed mode) JVM Command-line Options: -server -Xmn10500m -Xms12000m -Xmx12000m -XX:+UseHugeTLBFS -XX:+UseLargePages -XX:+UseTransparentHugePages -XX:AllocatePrefetchDistance=256 -XX:AllocatePrefetchInstr=0 -XX:AllocatePrefetchLines=4 -XX:InlineSmallCode=3900 -XX:MaxInlineSize=270 -XX:ParallelGCThreads=8 -XX:SurvivorRatio=1 -XX:TargetSurvivorRatio=99 -XX:+UseParallelOldGC -XX:FreqInlineSize=2500 -XX:MinJumpTableSize=18 -XX:UseAVX=0 -XX:+UseBiasedLocking -XX:-ThreadLocalHandshakes JVM Affinity: chrt -r 1 taskset -c 0,1,2,3,4,5,6,7,8,9,10,11 numactl --membind=0 JVM Instances: 1 JVM Initial Heap (MB): 12000 JVM Maximum Heap (MB): 12000 JVM Address Bits: 64 Boot Firmware Version: R1.30.0 Management Firmware Version: 1.01S Workload Version: SSJ 1.2.10 Director Location: Controller Other Software: None Boot Firmware Settings Set the following options in BIOS. * "ASPM Support = Auto" * "Hardware Prefetcher = Disabled" * "Adjacent Cache Line Prefetch = Disabled" * "Intel Virtualization Technology = Disabled" * "Software Guard Extensions (SGX) = Software Controlled" * "DDR Speed Control = Auto" * "DMI Gen3 ASPM = Auto" * "DMI Link ASPM Control = Auto" * "SATA Controller Port0/1/2/3/4/6 = Disabled" * "Serial Port = Disabled" * "LAN2 Controller = Disabled" Management Firmware Settings None System Under Test Notes * kernel parameter: pcie_aspm=force pcie_aspm.policy=powersave intel_pstate=passive * Benchmark started via ssh. * modprobe cpufreq_conservative * cpupower frequency-set -g conservative * echo 3000000 > /sys/devices/system/cpu/cpufreq/conservative/sampling_rate * echo 92 > /sys/devices/system/cpu/cpufreq/conservative/up_threshold * echo 1 > /sys/devices/system/cpu/cpufreq/conservative/freq_step * echo 91 > /sys/devices/system/cpu/cpufreq/conservative/down_threshold * echo always > /sys/kernel/mm/transparent_hugepage/enabled * cpupower frequency-set -u 3200MHz * sysctl -w kernel.nmi_watchdog=0 * echo 0000:00:14.0 > /sys/bus/pci/drivers/xhci_hcd/unbind * The test sponsor attests, as of date of publication, that CVE-2017-5754 (Meltdown) is mitigated in the system as tested and documented. * The test sponsor attests, as of date of publication, that CVE-2017-5753 (Spectre variant 1) is mitigated in the system as tested and documented. * The test sponsor attests, as of date of publication, that CVE-2017-5715 (Spectre variant 2) is mitigated in the system as tested and documented. Controller System HARDWARE Hardware Vendor: Fujitsu Model: PRIMERGY RX2530 M2 CPU Description: Intel Xeon E5-2643 v4 Memory amount (GB): 64 SOFTWARE Operating System (OS): Microsoft Windows Server 2012 R2 Standard JVM Vendor: Oracle Corporation JVM Version: Oracle Java HotSpot(TM) 64-Bit Server VM (build 25.211-b12, mixed mode), version 1.8.0_211 CCS Version: 1.2.6 Measurement Devices POWER ANALYZER PWR1 Hardware Vendor: Hioki Model: PW3336 Serial Number: 170134584 Connectivity: RS-232 Input Connection: Default Metrology Institute: NICT (National Institute of Information and Communications Technology) Accredited by: HIOKI E.E. CORPORATION Calibration Label: H06400087-2103 Date of Calibration: 08-Mar-2021 PTDaemon Host System: same as CCS PTDaemon Host OS: same as CCS PTDaemon Version: 1.9.2-3976349f-20201208 Setup Description: Connected to PSU 1 TEMPERATURE SENSOR TEMP1 Hardware Vendor: Digi International Inc. Model: Watchport/H Driver Version: Watchport Virtual Port 5.70.105.0 Connectivity: USB PTDaemon Host System: same as CCS PTDaemon Host OS: same as CCS Setup Description: 5 mm in front of SUT main air intake Notes * SPECpower_ssj.props input.load_level.number_warehouses set to 12. Aggregate Electrical and Environmental Data Target Load | Average | Minimum | Active | Ambient | Power (W) | Temperature | | (Degrees C) ----------- | ---------- | ------------- 100% | 58.9 | 28.1 90% | 50.7 | 28.2 80% | 43.7 | 29.4 70% | 39.0 | 28.1 60% | 34.0 | 29.1 50% | 30.2 | 28.1 40% | 26.8 | 27.7 30% | 24.0 | 29.2 20% | 21.6 | 28.5 10% | 19.0 | 27.4 Active Idle | 15.6 | 26.8 Line Standard | Minimum | Elevation (m) | Temperature | | (Degrees C) | ------------------------- | --------------- | --------------- 200V / 50 Hz / 1 phase / | 26.8 | 11 2 wires | | See the Power/Temperature Details Report (power_ssj2008-20211221-01146-power.txt) for additional details. Aggregate Performance Data Target Load | Actual Load | ssj_ops | | Target | Actual ----------------- | ----------------- | ----------------- | ----------------- Calibration 1 | | | 618,192 Calibration 2 | | | 660,389 Calibration 3 | | | 659,189 ssj_ops@calibrated=659,789 100% | 99.9% | 659,789 | 659,394 90% | 90.2% | 593,810 | 595,196 80% | 80.3% | 527,831 | 529,513 70% | 70.3% | 461,852 | 463,722 60% | 59.7% | 395,873 | 393,761 50% | 50.3% | 329,895 | 332,000 40% | 40.0% | 263,916 | 264,032 30% | 29.8% | 197,937 | 196,303 20% | 19.9% | 131,958 | 131,513 10% | 10.0% | 65,979 | 65,719 Active Idle | | 0 | 0 See the JVM Instance Performance Report (power_ssj2008-20211221-01146-localhost.001.txt) for additional details. Copyright (C) 2007-2022 Standard Performance Evaluation Corporation http://www.spec.org - info@spec.org SPECpower_ssj2008 Reporter Version: [SSJ 1.2.10, May 9, 2012]