Acer Incorporated Altos T350 F2 SPECpower_ssj2008 = 5,146 overall ssj_ops/watt
Test Sponsor: Acer Incorporated SPEC License #: 97 Test Method: Single Node
Tested By: Acer Incorporated Test Location: Taipei, R.O.C. Test Date: Jun 7, 2013
Hardware Availability: May-2013 Software Availability: Jun-2012 Publication: Jul 16, 2013
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 100.0% 1,310,610 219 5,990
90% 90.0% 1,179,813 193 6,122
80% 79.7% 1,045,097 167 6,256
70% 70.1% 918,581 147 6,235
60% 60.2% 788,768 130 6,061
50% 49.8% 652,972 115 5,665
40% 39.8% 521,792 107 4,885
30% 30.1% 394,683 98.5 4,009
20% 20.0% 262,679 89.0 2,951
10% 10.0% 130,678 78.7 1,661
Active Idle 0 56.1 0
∑ssj_ops / ∑power = 5,146
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: Acer Incorporated
Model: Altos T350 F2
Form Factor: 2U
CPU Name: Intel Xeon E5-2650 2.0 GHz (Intel Turbo Boost Technology up to 2.80 GHz)
CPU Characteristics: 8 core, 2.0 GHz, 20MB L3 Cache
CPU Frequency (MHz): 2000
CPU(s) Enabled: 16 cores, 2 chips, 8 cores/chip
Hardware Threads: 32 (2 / core)
CPU(s) Orderable: 1,2 chips
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 256 KB I+D on chip per core
Tertiary Cache: 20 MB I+D on chip per chip
Other Cache: None
Memory Amount (GB): 24
# and size of DIMM: 6 x 4096 MB
Memory Details: 4GB 2Rx8 PC3L-10600E; slots A1, B1, C1, E1, F1 and G1 populated
Power Supply Quantity and Rating (W): 1 x 750
Power Supply Details: Acer P/N SC.75017.002
Disk Drive: 1 x 240GB SSD 2.5" SATA, Acer P/N KN.2400N.002
Disk Controller: onboard SAS controller
# and type of Network Interface Cards (NICs) Installed: 1 x Quad-port Intel I350 Gigabit Ethernet controller
NICs Enabled in Firmware / OS / Connected: 1/1/1
Network Speed (Mbit): 1000
Keyboard: None
Mouse: None
Monitor: None
Optical Drives: No
Other Hardware: No
Software
Power Management: Power Saver Mode enabled in OS
Operating System (OS): Windows Server 2008, Enterprise Edition
OS Version: R2 SP1
Filesystem: NTFS
JVM Vendor: IBM Corporation
JVM Version: IBM J9 VM (build 2.6, JRE 1.7.0 Windows Server 2008 R2 amd64-64 20120322_106209 JIT enabled, AOT enabled)
JVM Command-line Options: -Xaggressive -Xcompressedrefs -Xmx1600m -Xms1600m -Xmn1200m -XlockReservation - Xnoloa -XtlhPrefetch -Xlp -Xconcurrentlevel0
JVM Affinity: start /affinity [0F,F0,F00,F000,F0000,F00000,F000000,F0000000]
JVM Instances: 8
JVM Initial Heap (MB): 1600
JVM Maximum Heap (MB): 1600
JVM Address Bits: 64
Boot Firmware Version: 01.06.0002
Management Firmware Version: 1.17.4151
Workload Version: SSJ 1.2.10
Director Location: Controller
Other Software: IBM SDK Java Technology Edition Version 7.0 for Windows x64
Boot Firmware Settings
Management Firmware Settings
None
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Acer Incorporated
Model: Acer AR160 F1
CPU Description: Xeon L5520
Memory amount (GB): 3
Software
Operating System (OS): Windows Server 2003 R2, Enterprise Edition SP2
JVM Vendor: Oracle Corporation
JVM Version: Oracle JRockit(R) (build R27.5.0-110_o-99226-1.6.0_03-20080528-1505-windows-ia32, compiled mode)
CCS Version: 1.2.6
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Electric International Pte. Ltd.
Model: WT210
Serial Number: 91H534921
Connectivity: RS232
Input Connection: Default
Metrology Institute: NML (National Measurement Laboratory, R.O.C.)
Accredited by: ETC, Taiwan
Calibration Label: 13-04-BAC-380-01
Date of Calibration: 9-May-2013
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.6.0-7f9b1b00-20130314
Setup Description: None
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: Watchport Virtual Port 5.0.0.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 5 mm in front of SUT airflow intake
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 219 22.7
90% 193 22.6
80% 167 22.2
70% 147 22.1
60% 130 22.1
50% 115 22.2
40% 107 22.1
30% 98.5 22.0
20% 89.0 22.0
10% 78.7 22.0
Active Idle 56.1 21.8
Line Standard Minimum Temperature (°C) Elevation (m)
220V / 60 Hz / 1 phase / 2 wires 21.8 132
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     1,262,610
Calibration 2     1,310,239
Calibration 3     1,310,781
ssj_ops@calibrated=1,310,510
100% 100.0% 1,310,510 1,310,610
90% 90.0% 1,179,459 1,179,813
80% 79.7% 1,048,408 1,045,097
70% 70.1% 917,357 918,581
60% 60.2% 786,306 788,768
50% 49.8% 655,255 652,972
40% 39.8% 524,204 521,792
30% 30.1% 393,153 394,683
20% 20.0% 262,102 262,679
10% 10.0% 131,051 130,678
Active Idle   0 0