Huawei Technologies Co., Ltd RH2288 V2 SPECpower_ssj2008 = 5,453 overall ssj_ops/watt
Test Sponsor: Huawei Technologies Co., Ltd SPEC License #: 3175 Test Method: Single Node
Tested By: Huawei Technologies Co., Ltd Test Location: Shenzhen, Guangdong, China Test Date: Oct 13, 2012
Hardware Availability: Aug-2012 Software Availability: Jun-2012 Publication: Oct 31, 2012
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 100.0% 1,445,741 239 6,057
90% 89.8% 1,299,178 217 5,979
80% 80.0% 1,156,638 182 6,357
70% 69.9% 1,010,701 155 6,531
60% 59.9% 866,974 134 6,450
50% 50.0% 723,736 116 6,229
40% 40.1% 579,900 105 5,516
30% 30.0% 434,347 96.4 4,506
20% 20.0% 288,645 86.4 3,339
10% 10.0% 144,142 75.2 1,917
Active Idle 0 51.5 0
∑ssj_ops / ∑power = 5,453
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: Huawei Technologies Co., Ltd
Model: RH2288 V2
Form Factor: 2U
CPU Name: Intel Xeon E5-2660
CPU Characteristics: 8-Core, 2.20 GHz, 20 MB L3 Cache (Intel Turbo Boost Technology up to 3.00 GHz)
CPU Frequency (MHz): 2200
CPU(s) Enabled: 16 cores, 2 chips, 8 cores/chip
Hardware Threads: 32 (2 / core)
CPU(s) Orderable: 1,2 chips
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 256 KB I+D on chip per core
Tertiary Cache: 20 MB I+D on chip per chip
Other Cache: None
Memory Amount (GB): 24
# and size of DIMM: 6 x 4 GB
Memory Details: 4GB 2Rx8 PC3L-10600R ECC RDIMM, Slots A1 B1,C1, D1, E1,F1,populated
Power Supply Quantity and Rating (W): 1 x 460
Power Supply Details: Huawei P/N PW98080438
Disk Drive: 1 x 160GB SSD 2.5" SATA Huawei P/N 02310KSX
Disk Controller: Integrated SATA controller
# and type of Network Interface Cards (NICs) Installed: 1 x Dual-port Intel 82580 Gigabit Ethernet controller
NICs Enabled in Firmware / OS / Connected: 2/2/1
Network Speed (Mbit): 1000
Keyboard: None
Mouse: None
Monitor: None
Optical Drives: No
Other Hardware: None
Software
Power Management: Power Saver enabled in OS
Operating System (OS): Microsoft Windows Server 2008 Enterprise x64 Edition
OS Version: R2 SP1
Filesystem: NTFS
JVM Vendor: IBM Corporation
JVM Version: IBM J9 VM (build 2.6,JRE 1.7.0 Windows Server 2008 R2 amd64-64 20120322_106209 (JIT enabled, AOT enabled)
JVM Command-line Options: -Xaggressive -Xcompressedrefs -Xmx1500m -Xms1500m -Xmn1100m -XlockReservation -Xnoloa -XtlhPrefetch -Xlp -Xconcurrentlevel0
JVM Affinity: start /affinity [0x0F,0xF0,0xF00,0xF000,0xF0000,0xF00000,0xF000000,0xF0000000]
JVM Instances: 8
JVM Initial Heap (MB): 1500
JVM Maximum Heap (MB): 1500
JVM Address Bits: 64
Boot Firmware Version: V030
Management Firmware Version: 3.02
Workload Version: SSJ 1.2.9
Director Location: Controller
Other Software: IBM WebSphere Application Server V7.0 for Windows on x86-64bit
Boot Firmware Settings
Management Firmware Settings
none
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Huawei Technologies Co., Ltd
Model: Tecal RH2280 Rack Server
CPU Description: Intel Xeon 5205
Memory amount (GB): 6
Software
Operating System (OS): Microsoft Windows Server 2003 SP2
JVM Vendor: Oracle
JVM Version: Oracle Java HotSpot(TM) 64-Bit Server VM on Windows, version 1.6.0_30
CCS Version: 1.2.5
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Meters and Instruments Corporation
Model: WT210
Serial Number: 91K630156
Connectivity: RS-232
Input Connection: Default
Metrology Institute: CNAS (China National Accreditation Service for Conformity Assessment)
Accredited by: Calibration and Testing Center of CEPREI
Calibration Label: "2GB12006186-0010"
Date of Calibration: 30-Jul-2012
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.4.1-1271fb18-20110728
Setup Description: none
Temperature Sensor temp1
Hardware Vendor: Temperature@lert
Model: TM-STD30
Driver Version: 3.1.0.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: Use a 2 meters USB extension cable to connect to the controller. And placed in front the main airflow inlet of the SUT less than 50mm.
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 239 22.9
90% 217 22.9
80% 182 22.9
70% 155 23.0
60% 134 23.0
50% 116 23.0
40% 105 23.1
30% 96.4 23.1
20% 86.4 23.1
10% 75.2 23.1
Active Idle 51.5 23.1
Line Standard Minimum Temperature (°C) Elevation (m)
220V / 50 Hz / 1 phase / 2 wires 22.9 101
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     1,306,639
Calibration 2     1,445,087
Calibration 3     1,447,401
ssj_ops@calibrated=1,446,244
100% 100.0% 1,446,244 1,445,741
90% 89.8% 1,301,620 1,299,178
80% 80.0% 1,156,995 1,156,638
70% 69.9% 1,012,371 1,010,701
60% 59.9% 867,746 866,974
50% 50.0% 723,122 723,736
40% 40.1% 578,498 579,900
30% 30.0% 433,873 434,347
20% 20.0% 289,249 288,645
10% 10.0% 144,624 144,142
Active Idle   0 0
Graph of results