Dell Inc. PowerEdge R520 (Intel Xeon E5-2470, 2.30 GHz) SPECpower_ssj2008 = 5,504 overall ssj_ops/watt
Test Sponsor: Dell Inc. SPEC License #: 55 Test Method: Single Node
Tested By: Dell Inc. Test Location: Round Rock, TX, USA Test Date: Oct 2, 2012
Hardware Availability: Jun-2012 Software Availability: Jun-2012 Publication: Oct 17, 2012
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.1% 1,496,064 264 5,677
90% 89.8% 1,354,870 218 6,212
80% 79.8% 1,204,865 188 6,408
70% 70.1% 1,057,520 168 6,292
60% 59.9% 904,142 142 6,389
50% 50.0% 754,760 123 6,160
40% 40.1% 606,017 112 5,432
30% 30.0% 453,109 93.9 4,824
20% 20.0% 302,374 80.4 3,761
10% 10.0% 151,435 69.7 2,174
Active Idle 0 47.9 0
∑ssj_ops / ∑power = 5,504
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: PowerEdge R520
Hardware
Hardware Vendor: Dell Inc.
Model: PowerEdge R520 (Intel Xeon E5-2470, 2.30 GHz)
Form Factor: 2U
CPU Name: Intel Xeon E5-2470 (Intel Turbo Boost Technology up to 3.10 GHz )
CPU Characteristics: 8 core, 2.30GHz, 20MB L3 Cache
CPU Frequency (MHz): 2300
CPU(s) Enabled: 16 cores, 2 chips, 8 cores/chip
Hardware Threads: 32 (2 / core)
CPU(s) Orderable: 1, 2 chips
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 256 KB I+D on chip per core
Tertiary Cache: 20 MB I+D on chip per chip
Other Cache: None
Memory Amount (GB): 24
# and size of DIMM: 6 x 4096 MB
Memory Details: 4GB 2Rx8 PC3L-10600E-9 ECC; Slots A1-3,B1-3 populated.
Power Supply Quantity and Rating (W): 1 x 750
Power Supply Details: Dell P/N XYXMG
Disk Drive: 1 x 100GB SATA SSD, Dell P/N DYW42
Disk Controller: PERC S110
# and type of Network Interface Cards (NICs) Installed: 1 x dual-port Broadcom 5720
NICs Enabled in Firmware / OS / Connected: 2/2/1
Network Speed (Mbit): 1000
Keyboard: None
Mouse: None
Monitor: None
Optical Drives: No
Other Hardware: None
Software
Power Management: Power Saver plan in OS
Operating System (OS): Microsoft Windows Server 2008 x64 Enterprise Edition
OS Version: R2 SP1
Filesystem: NTFS
JVM Vendor: IBM Corporation
JVM Version: IBM J9 VM (build 2.6,JRE 1.7.0 Windows Server 2008 R2 amd64-64 20120322_106209 (JIT enabled, AOT enabled)
JVM Command-line Options: -Xaggressive -Xcompressedrefs -Xmx1024m -Xms1024m -Xmn800m -XlockReservation -Xnoloa -XtlhPrefetch -Xlp -Xconcurrentlevel0
JVM Affinity: start /affinity [3,C,30,C00,300,C00,3000,C000,30000,C0000,300000,C00000,3000000,C000000,30000000,C0000000]
JVM Instances: 16
JVM Initial Heap (MB): 1024
JVM Maximum Heap (MB): 1024
JVM Address Bits: 64
Boot Firmware Version: 1.2.4
Management Firmware Version: 1.20.20 (Build 24)
Workload Version: SSJ 1.2.10
Director Location: Controller
Other Software: IBM SDK Java Technology Edition Version 7.0 for Windows x64
Boot Firmware Settings
Management Firmware Settings
none
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Dell Inc
Model: Poweredge 1950
CPU Description: Inel Xeon E5470, 3.33 GHz
Memory amount (GB): 8.0
Software
Operating System (OS): Microsoft Windows Server 2003 Enterprise Edition Service Pack 2
JVM Vendor: Oracle Corporation
JVM Version: Hotspot(TM) Client VM, version 1.6.0_32
CCS Version: 1.2.6
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Meters and Instruments Corporation
Model: WT210
Serial Number: 91KA25149
Connectivity: RS-232
Input Connection: Default
Metrology Institute: NIST
Accredited by: SIMCO
Calibration Label: 5477872
Date of Calibration: 16-Dec-2011
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.4.2-bc965ca0-20120417
Setup Description: Connected to power supply
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: 5.30.2.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 25 mm in front of SUT main airflow intake
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 264 20.1
90% 218 20.1
80% 188 20.1
70% 168 20.1
60% 142 20.2
50% 123 20.2
40% 112 20.2
30% 93.9 20.2
20% 80.4 20.2
10% 69.7 20.2
Active Idle 47.9 20.8
Line Standard Minimum Temperature (°C) Elevation (m)
208V / 60 Hz / 1 phase / 2 wires 20.1 255
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     1,436,962
Calibration 2     1,509,665
Calibration 3     1,509,521
ssj_ops@calibrated=1,509,593
100% 99.1% 1,509,593 1,496,064
90% 89.8% 1,358,634 1,354,870
80% 79.8% 1,207,674 1,204,865
70% 70.1% 1,056,715 1,057,520
60% 59.9% 905,756 904,142
50% 50.0% 754,796 754,760
40% 40.1% 603,837 606,017
30% 30.0% 452,878 453,109
20% 20.0% 301,919 302,374
10% 10.0% 150,959 151,435
Active Idle   0 0
Graph of results