IBM Corporation IBM System x3200 M2 SPECpower_ssj2008 = 605 overall ssj_ops/watt
Test Sponsor: Intel Corp. SPEC License #: 3184 Test Method: Single Node
Tested By: Principled Technologies, Inc. Test Location: Durham, NC, USA Test Date: Jan 19, 2011
Hardware Availability: Jan-2008 Software Availability: May-2009 Publication: Feb 17, 2011
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 100.1% 118,486 117 1,009
90% 90.4% 107,029 115 931
80% 81.0% 95,930 112 855
70% 70.1% 82,922 109 764
60% 60.1% 71,121 105 680
50% 50.2% 59,447 100 593
40% 40.5% 47,920 94.9 505
30% 29.6% 35,056 89.6 391
20% 19.9% 23,574 84.1 280
10% 10.4% 12,321 78.2 158
Active Idle 0 75.2 0
∑ssj_ops / ∑power = 605
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: IBM System x3200 M2
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: IBM Corporation
Model: IBM System x3200 M2
Form Factor: Tower
CPU Name: Intel Xeon Processor E3110
CPU Characteristics: Dual-Core, 3.00 GHz, 6 MB L2 Cache, 1333 MHz system bus
CPU Frequency (MHz): 3000
CPU(s) Enabled: 2 cores, 1 chip, 2 cores/chip
Hardware Threads: 2 (1 / core)
CPU(s) Orderable: 1 chip
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 6 MB I+D on chip per chip
Tertiary Cache: None
Other Cache: None
Memory Amount (GB): 4
# and size of DIMM: 4 x 1024 MB
Memory Details: 1 GB 2Rx8 PC2-6400E; all slots populated
Power Supply Quantity and Rating (W): 1 x 400
Power Supply Details: Delta Electronics DPS400MB-1A
Disk Drive: 2 x 160 GB 7.2K RPM SATA RAID 1
Disk Controller: Four-port LSI 1064e SAS/SATA
# and type of Network Interface Cards (NICs) Installed: 1 x Broadcom NetXtreme Gigabit Ethernet
NICs Enabled in Firmware / OS / Connected: 1/1/1
Network Speed (Mbit): 1000
Keyboard: KVM
Mouse: KVM
Monitor: KVM
Optical Drives: Yes
Other Hardware: None
Software
Power Management: Enabled (see SUT Notes)
Operating System (OS): Microsoft Windows Server 2003, Enterprise x64 Edition
OS Version: Build 3790
Filesystem: NTFS
JVM Vendor: Oracle Corporation
JVM Version: Oracle JRockit(R) (build P28.0.0-29-114096-1.6.0_11-20090427-1759-windows-x86_64, compiled mode)
JVM Command-line Options: -Xms2800m -Xmx2800m -Xns2660m -XXaggressive -XXlargePages -XXthroughputCompaction -XXcallprofiling -XXlazyUnlocking -Xgc:genpar -XXgcthreads:2 -XXtlasize:min=12k,preferred=1024k
JVM Affinity: None
JVM Instances: 1
JVM Initial Heap (MB): 2800
JVM Maximum Heap (MB): 2800
JVM Address Bits: 64
Boot Firmware Version: 1.47 2010.12.20
Management Firmware Version: 1.06 2008.08.07
Workload Version: SSJ 1.2.6
Director Location: Controller
Other Software: None
Boot Firmware Settings
Hardware Prefetcher disabled in BIOS, Adjacent Cache Line Prefetch disabled in BIOS
Management Firmware Settings
Default
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Super Micro Computer, Inc.
Model: Supermicro 6025W-NTR+V
CPU Description: Intel Xeon Processor E5472
Memory amount (GB): 16
Software
Operating System (OS): Microsoft Windows Server 2003, Enterprise Edition, Service Pack 2
JVM Vendor: BEA Systems, Inc.
JVM Version: BEA JRockit(R) (build R27.5.0-110_o-99226-1.5.0_14-20080528-1505-windows-ia32, compiled mode)
CCS Version: 1.2.4
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Electric International Pte. Ltd.
Model: WT210
Serial Number: 91GB45373
Connectivity: RS-232
Input Connection: Default
Calibration Institute: NIST
Accredited by: Davis Calibration
Calibration Label: 07-1673
Date of Calibration: 28-Jul-2010
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.4.0-7071d9e7
Setup Description: SUT Power Supply
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: 5.10.26.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 50 mm in front of SUT main air intake
Notes
Used USB-to-Serial converter, Model Sabrent SBT-USC1M (driver version 2.0.2.1), to connect power analyzer to the controller.

This benchmark result is intended to provide perspective on past power and/or performance using the historical hardware and/or software described on this result page.

The system as described on this result page was formerly generally available. At the time of this publication, it may not be shipping, and/or may not be supported, and/or may fail to meet other tests of General Availability described in the SPEC OSG Policy document, http://www.spec.org/osg/policy.html

This measured result may not be representative of the result that would be measured were this benchmark run with hardware and software available as of the publication date.

Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 117 26.6
90% 115 26.7
80% 112 26.8
70% 109 26.9
60% 105 26.9
50% 100 26.9
40% 94.9 26.9
30% 89.6 26.6
20% 84.1 26.3
10% 78.2 26.2
Active Idle 75.2 26.0
Line Standard Minimum Temperature (°C) Elevation (m)
120V / 60 Hz / 1 phase / 2 wires 26.0 132
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     118,521
Calibration 2     118,271
Calibration 3     118,474
ssj_ops@calibrated=118,372
100% 100.1% 118,372 118,486
90% 90.4% 106,535 107,029
80% 81.0% 94,698 95,930
70% 70.1% 82,861 82,922
60% 60.1% 71,023 71,121
50% 50.2% 59,186 59,447
40% 40.5% 47,349 47,920
30% 29.6% 35,512 35,056
20% 19.9% 23,674 23,574
10% 10.4% 11,837 12,321
Active Idle   0 0
Graph of results