Hewlett-Packard Company ProLiant DL580 G4 SPECpower_ssj2008 = 114 overall ssj_ops/watt
Test Sponsor: Intel Corp. SPEC License #: 3184 Test Method: Single Node
Tested By: Principled Technologies, Inc. Test Location: Durham, NC, USA Test Date: Jan 20, 2011
Hardware Availability: Aug-2006 Software Availability: May-2009 Publication: Feb 17, 2011
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.2% 148,741 732 203
90% 89.6% 134,366 716 188
80% 79.4% 119,107 704 169
70% 69.7% 104,576 690 152
60% 60.3% 90,456 673 134
50% 50.0% 74,987 656 114
40% 39.9% 59,860 639 93.7
30% 29.9% 44,863 623 72.0
20% 20.4% 30,563 607 50.3
10% 9.9% 14,880 590 25.2
Active Idle 0 575 0
∑ssj_ops / ∑power = 114
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: ProLiant DL580 G4
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: Hewlett-Packard Company
Model: ProLiant DL580 G4
Form Factor: 4U
CPU Name: Intel Xeon Processor 7110M
CPU Characteristics: Dual-Core, 2.60 GHz, 4 MB L2 Cache, 800 MHz system bus
CPU Frequency (MHz): 2600
CPU(s) Enabled: 8 cores, 4 chips, 2 cores/chip
Hardware Threads: 16 (2 / core)
CPU(s) Orderable: 4 chips
Primary Cache: 16 KB I + 16 KB D on chip per core
Secondary Cache: 4 MB I+D on chip per chip
Tertiary Cache: None
Other Cache: None
Memory Amount (GB): 16
# and size of DIMM: 16 x 1024 MB
Memory Details: 1GB 1Rx4 PC2-3200R; all slots populated
Power Supply Quantity and Rating (W): 2 x 1300
Power Supply Details: HP part #337867-501
Disk Drive: 2 x 146GB 10K RPM SAS RAID 1
Disk Controller: HP Smart Array P400 with 512MB of RAM
# and type of Network Interface Cards (NICs) Installed: 2 x NC371i Multifunction Gigabit Network Adapters
NICs Enabled in Firmware / OS / Connected: 2/1/1
Network Speed (Mbit): 1000
Keyboard: KVM
Mouse: KVM
Monitor: KVM
Optical Drives: Yes
Other Hardware: None
Software
Power Management: Enabled (see SUT Notes)
Operating System (OS): Microsoft Windows Server 2008, Enterprise x64 Edition
OS Version: SP2, Build 6002
Filesystem: NTFS
JVM Vendor: Oracle Corporation
JVM Version: Oracle JRockit(R) (build P28.0.0-29-114096-1.6.0_11-20090427-1759-windows-x86_64, compiled mode)
JVM Command-line Options: -Xms3200m -Xmx3200m -Xns2880m -XXaggressive -XXlargePages -XXthroughputCompaction -XXcallprofiling -XXlazyUnlocking -Xgc:genpar -XXgcthreads:4 -XXtlasize:min=12k,preferred=1024k
JVM Affinity: Start /affinity [F, F0, F00, F000]
JVM Instances: 4
JVM Initial Heap (MB): 3200
JVM Maximum Heap (MB): 3200
JVM Address Bits: 64
Boot Firmware Version: P59 2008.06.10
Management Firmware Version: 1.81 01/15/2010
Workload Version: SSJ 1.2.6
Director Location: Controller
Other Software: None
Boot Firmware Settings
Hardware Prefetcher disabled in BIOS, Adjacent Cache Line Prefetch disabled in BIOS, HP Dynamic Power Savings Mode Enabled in BIOS
Management Firmware Settings
Default
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Super Micro Computer, Inc.
Model: Supermicro 6025W-NTR+V
CPU Description: Intel Xeon Processor E5472
Memory amount (GB): 16
Software
Operating System (OS): Microsoft Windows Server 2003, Enterprise Edition, Service Pack 2
JVM Vendor: BEA Systems, Inc.
JVM Version: BEA JRockit(R) (build R27.5.0-110_o-99226-1.5.0_14-20080528-1505-windows-ia32, compiled mode)
CCS Version: 1.2.4
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Electric International Pte. Ltd.
Model: WT210
Serial Number: 91GB45373
Connectivity: RS-232
Input Connection: Default
Calibration Institute: NIST
Accredited by: Davis Calibration
Calibration Label: 07-1673
Date of Calibration: 28-Jul-2010
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.4.0-7071d9e7
Setup Description: SUT Power Supply
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: 5.10.26.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 50 mm in front of SUT main air intake
Notes
Used USB-to-Serial converter, Model Sabrent SBT-USC1M (driver version 2.0.2.1), to connect power analyzer to the controller.

This benchmark result is intended to provide perspective on past power and/or performance using the historical hardware and/or software described on this result page.

The system as described on this result page was formerly generally available. At the time of this publication, it may not be shipping, and/or may not be supported, and/or may fail to meet other tests of General Availability described in the SPEC OSG Policy document, http://www.spec.org/osg/policy.html

This measured result may not be representative of the result that would be measured were this benchmark run with hardware and software available as of the publication date.

Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 732 20.3
90% 716 20.2
80% 704 20.6
70% 690 20.2
60% 673 20.3
50% 656 20.4
40% 639 20.2
30% 623 20.6
20% 607 20.2
10% 590 20.2
Active Idle 575 20.3
Line Standard Minimum Temperature (°C) Elevation (m)
208V / 60 Hz / 1 phase / 2 wires 20.2 132
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     148,664
Calibration 2     149,618
Calibration 3     150,337
ssj_ops@calibrated=149,978
100% 99.2% 149,978 148,741
90% 89.6% 134,980 134,366
80% 79.4% 119,982 119,107
70% 69.7% 104,984 104,576
60% 60.3% 89,987 90,456
50% 50.0% 74,989 74,987
40% 39.9% 59,991 59,860
30% 29.9% 44,993 44,863
20% 20.4% 29,996 30,563
10% 9.9% 14,998 14,880
Active Idle   0 0
Graph of results