Fujitsu PRIMERGY TX150 S7 (Intel Xeon X3480) SPECpower_ssj2008 = 2,513 overall ssj_ops/watt
Test Sponsor: Fujitsu SPEC License #: 19 Test Method: Single Node
Tested By: Fujitsu Test Location: Paderborn, NRW, Germany Test Date: Oct 20, 2010
Hardware Availability: Jun-2010 Software Availability: Nov-2009 Publication: Dec 1, 2010
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 100.1% 330,353 113 2,934
90% 90.8% 299,373 103 2,896
80% 80.2% 264,454 89.7 2,947
70% 70.4% 232,261 78.3 2,965
60% 59.9% 197,591 69.0 2,862
50% 50.3% 166,009 61.9 2,681
40% 40.3% 133,067 55.6 2,392
30% 30.0% 98,925 49.7 1,989
20% 20.1% 66,426 43.7 1,519
10% 10.0% 32,964 36.0 915
Active Idle 0 24.8 0
∑ssj_ops / ∑power = 2,513
Graph of results
System Under Test
Set: 'SUT'
Set Identifier: SUT
Set Description: System Under Test
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: Fujitsu
Model: PRIMERGY TX150 S7 (Intel Xeon X3480)
Form Factor: Tower
CPU Name: Intel Xeon X3480
CPU Characteristics: Quad-Core, 3.06GHz, 8MB L3 Cache
CPU Frequency (MHz): 3067
CPU(s) Enabled: 4 cores, 1 chip, 4 cores/chip
Hardware Threads: 8 (2 / core)
CPU(s) Orderable: 1 chip
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 256 KB I+D on chip per core
Tertiary Cache: 8 MB I+D on chip per chip
Other Cache: None
Memory Amount (GB): 4
# and size of DIMM: 2 x 2048 MB
Memory Details: 2GB 2Rx8 PC3-10600E ECC CL9; slots 1A, 1B populated
Power Supply Quantity and Rating (W): 1 x 350
Power Supply Details: Fujitsu Technology Solutions S26113-E549-V50-01
Disk Drive: 1 x 32GB SSD 2.5" SATA (Fujitsu S26361-F3298-E32)
Disk Controller: Integrated SATA Controller
# and type of Network Interface Cards (NICs) Installed: 1 x Intel 82574L Gigabit Network Connection (onboard)
NICs Enabled in Firmware / OS / Connected: 1/1/1
Network Speed (Mbit): 1000
Keyboard: None
Mouse: None
Monitor: None
Optical Drives: No
Other Hardware: None
Software
Power Management: Enabled ("Fujitsu Enhanced Power Settings" power plan)
Operating System (OS): Microsoft Windows Server 2008 R2 Enterprise
OS Version: Version 6.1.7600 Build 7600
Filesystem: NTFS
JVM Vendor: IBM Corporation
JVM Version: IBM J9 VM (build 2.4, JRE 1.6.0 IBM J9 2.4 Windows Server 2008 amd64-64 jvmwa6460sr6-20090923_42924 (JIT enabled, AOT enabled)
JVM Command-line Options: -Xaggressive -Xcompressedrefs -Xgcpolicy:gencon -Xmn1000m -Xms1350m -Xmx1350m -XlockReservation -Xnoloa -XtlhPrefetch -Xlp
JVM Affinity: start /affinity [0x0F,0xF0]
JVM Instances: 2
JVM Initial Heap (MB): 1350
JVM Maximum Heap (MB): 1350
JVM Address Bits: 64
Boot Firmware Version: 1.07
Management Firmware Version: 5.08A
Workload Version: SSJ 1.2.6
Director Location: Controller
Other Software: IBM Websphere application server V7.0 for Windows on X86-64bit
Boot Firmware Settings
Management Firmware Settings
None
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Fujitsu
Model: PRIMERGY RX100 S3
CPU Description: Pentium D 950
Memory amount (GB): 2
Software
Operating System (OS): Windows Server 2003 Enterprise Edition + SP1
JVM Vendor: Oracle Corporation
JVM Version: Oracle JRockit(R) R27.6.0 (build R27.6.0-50_o-100423-1.6.0_05-20080626-2105-windows-ia32)
CCS Version: 1.2.4
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa
Model: WT210
Serial Number: 91HA48097
Connectivity: RS-232
Input Connection: Default (20A)
Calibration Institute: PTB (Physikalisch Technische Bundesanstalt)
Accredited by: Kalibrierdienst Stenger
Calibration Label: 09116242
Date of Calibration: 20-Nov-2009
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.4.0-7071d9e7
Setup Description: SUT Power Supply 1
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: Watchport Virtual Port 5.10.26.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 5 mm in front of SUT main air intake
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 113 20.3
90% 103 20.2
80% 89.7 20.2
70% 78.3 20.2
60% 69.0 20.1
50% 61.9 20.1
40% 55.6 20.1
30% 49.7 20.1
20% 43.7 20.1
10% 36.0 20.1
Active Idle 24.8 20.1
Line Standard Minimum Temperature (°C) Elevation (m)
230V / 50 Hz / 1 phase / 2 wires 20.1 117
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     327,462
Calibration 2     328,894
Calibration 3     330,854
ssj_ops@calibrated=329,874
100% 100.1% 329,874 330,353
90% 90.8% 296,886 299,373
80% 80.2% 263,899 264,454
70% 70.4% 230,912 232,261
60% 59.9% 197,924 197,591
50% 50.3% 164,937 166,009
40% 40.3% 131,949 133,067
30% 30.0% 98,962 98,925
20% 20.1% 65,975 66,426
10% 10.0% 32,987 32,964
Active Idle   0 0
Graph of results