Acer Incorporated Gateway GT310 F1 (Intel Xeon X3470, 2.93 GHz) SPECpower_ssj2008 = 1,987 overall ssj_ops/watt
Test Sponsor: Acer Incorporated SPEC License #: 97 Test Method: Single Node
Tested By: Acer Incorporated Test Location: Taipei, Taiwan, ROC Test Date: Oct 22, 2010
Hardware Availability: Mar-2010 Software Availability: Dec-2009 Publication: Dec 1, 2010
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.5% 313,001 127 2,467
90% 90.1% 283,624 116 2,435
80% 79.6% 250,370 106 2,363
70% 69.4% 218,475 96.7 2,259
60% 59.8% 188,151 87.5 2,151
50% 50.0% 157,220 78.0 2,015
40% 40.2% 126,502 68.6 1,843
30% 30.0% 94,505 59.7 1,582
20% 20.0% 62,853 51.1 1,230
10% 10.0% 31,319 43.0 728
Active Idle 0 34.6 0
∑ssj_ops / ∑power = 1,987
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: Acer Incorporated
Model: Gateway GT310 F1 (Intel Xeon X3470, 2.93 GHz)
Form Factor: Tower
CPU Name: Intel Xeon X3470
CPU Characteristics: Quad-Core, 2.93GHz, 8MB L3 Cache
CPU Frequency (MHz): 2933
CPU(s) Enabled: 4 cores, 1 chip, 4 cores/chip
Hardware Threads: 8 (2 / core)
CPU(s) Orderable: 1 chip
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 256 KB I+D on chip per core
Tertiary Cache: 8 MB I+D on chip per chip
Other Cache: None
Memory Amount (GB): 8
# and size of DIMM: 2 x 4096 MB
Memory Details: 4GB 2Rx8 PC3-10600R; slots 1A and 2A are populated
Power Supply Quantity and Rating (W): 1 x 450
Power Supply Details: FSP450-60EP
Disk Drive: 1 x 64GB SSD 2.5" SATA, Acer P/N:KF.0640N.001
Disk Controller: Integrated SATA controller
# and type of Network Interface Cards (NICs) Installed: 2 x single-port Intel 82574L Gigabit Ethernet controller
NICs Enabled in Firmware / OS / Connected: 1/1/1
Network Speed (Mbit): 1000
Keyboard: KVM
Mouse: KVM
Monitor: KVM
Optical Drives: Yes
Other Hardware: None
Software
Power Management: Balance power enabled in OS
Operating System (OS): Microsoft Windows Server 2008 R2 Enterprise Edition
OS Version: 6.1.7600 Build 7600
Filesystem: NTFS
JVM Vendor: IBM Corporation
JVM Version: IBM J9 VM <build 2.4, JRE 1.6.0 IBM J9 2.4 Windows Server 2008 amd64-64 jvmwa6460sr7-20091214_049398 <JIT enabled, AOT enabled>
JVM Command-line Options: -Xaggressive -Xcompressedrefs -Xgcpolicy:gencon -Xmn1400m -ms1875m -Xmx1875m -XlockReservation -Xnoloa -XtlhPrefetch -Xlp
JVM Affinity: start /affinity [0F,F0]
JVM Instances: 2
JVM Initial Heap (MB): 1875
JVM Maximum Heap (MB): 1875
JVM Address Bits: 64
Boot Firmware Version: P05
Management Firmware Version: 01.40
Workload Version: SSJ 1.2.6
Director Location: SUT
Other Software: IBM Websphere Application Server V7.0 for Windows on x86-64bit
Boot Firmware Settings
Management Firmware Settings
None
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Acer Incorporated
Model: Gateway GT110 F1
CPU Description: Xeon UP Quad-Core E3110
Memory amount (GB): 4
Software
Operating System (OS): Windows Server 2003 R2 Enterprise Edition SP2
JVM Vendor: Oracle Corporation
JVM Version: Oracle JRockit(R) 6 P28.0.0 (build P28.0.0-29-114096-1.6.0_11-20090427-1759-windows-x86)
CCS Version: 1.2.4
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa
Model: WT210
Serial Number: 91GC17356
Connectivity: RS-232-C
Input Connection: Default
Calibration Institute: NML (National Measurement Laboratory, R.O.C.)
Accredited by: Tai Yi Electronics & Surveillance Co., Ltd.
Calibration Label: T9903260701
Date of Calibration: 30-Mar-2010
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.4.0-7071d9e7
Setup Description: SUT Power Supply 1
Temperature Sensor temp1
Hardware Vendor: Temperature@lert
Model: Temperature@lert
Driver Version: 2.6.0.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 50 mm in front of SUT main intake
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 127 23.5
90% 116 23.6
80% 106 23.8
70% 96.7 23.9
60% 87.5 24.1
50% 78.0 24.1
40% 68.6 24.3
30% 59.7 24.2
20% 51.1 23.9
10% 43.0 23.9
Active Idle 34.6 23.8
Line Standard Minimum Temperature (°C) Elevation (m)
120V / 60 Hz / 1 phase / 2 wires 23.5 1
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     313,352
Calibration 2     314,744
Calibration 3     314,620
ssj_ops@calibrated=314,682
100% 99.5% 314,682 313,001
90% 90.1% 283,213 283,624
80% 79.6% 251,745 250,370
70% 69.4% 220,277 218,475
60% 59.8% 188,809 188,151
50% 50.0% 157,341 157,220
40% 40.2% 125,873 126,502
30% 30.0% 94,404 94,505
20% 20.0% 62,936 62,853
10% 10.0% 31,468 31,319
Active Idle   0 0
Graph of results