Acer Incorporated Acer AT350 F1 (Intel Xeon X5670, 2.93 GHz) SPECpower_ssj2008 = 2,518 overall ssj_ops/watt
Test Sponsor: Acer Incorporated SPEC License #: 97 Test Method: Single Node
Tested By: Acer Incorporated Test Location: Taipei, R.O.C. Test Date: Sep 14, 2010
Hardware Availability: Jun-2010 Software Availability: Dec-2009 Publication: Oct 6, 2010
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.6% 905,850 259 3,493
90% 89.6% 815,054 243 3,355
80% 79.9% 726,302 229 3,166
70% 70.0% 636,771 214 2,969
60% 60.1% 546,532 198 2,760
50% 50.1% 455,907 180 2,526
40% 39.9% 362,751 164 2,214
30% 29.8% 271,362 150 1,810
20% 20.2% 183,438 139 1,316
10% 10.0% 90,769 127 714
Active Idle 0 78.8 0
∑ssj_ops / ∑power = 2,518
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: Acer Incorporated
Model: Acer AT350 F1 (Intel Xeon X5670, 2.93 GHz)
Form Factor: Tower
CPU Name: Intel Xeon X5670
CPU Characteristics: Six-Core, 2.93 GHz, 12 MB L3 cache
CPU Frequency (MHz): 2933
CPU(s) Enabled: 12 cores, 2 chips, 6 cores/chip
Hardware Threads: 24 (2 / core)
CPU(s) Orderable: 1,2 chips
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 256 KB I+D on chip per core
Tertiary Cache: 12 MB I+D on chip per chip
Other Cache: None
Memory Amount (GB): 12
# and size of DIMM: 6 x 2048 MB
Memory Details: 2GB 2Rx8 PC3-10600E; slots 1A, 2A, and 3A populated on each processor
Power Supply Quantity and Rating (W): 1 x 720
Power Supply Details: PWS-721P-1R
Disk Drive: 1 x 64GB SSD 2.5" SATA, Acer Part#KF.0640N.001
Disk Controller: onboard SATA controller
# and type of Network Interface Cards (NICs) Installed: 1 x Dual-port Intel 82576EB Gigabit Ethernet controller
NICs Enabled in Firmware / OS / Connected: 2/2/1
Network Speed (Mbit): 1000
Keyboard: PS2
Mouse: PS2
Monitor: Direct
Optical Drives: No
Other Hardware: None
Software
Power Management: Power save enabled in OS
Operating System (OS): Windows Server 2008, Enterprise Edition
OS Version: R2
Filesystem: NTFS
JVM Vendor: IBM Corporation
JVM Version: IBM J9 VM (build 2.4, JRE 1.6.0 IBM J9 2.4 Windows Server 2008 amd64-64 jvmwa6460sr7-20091214_49398 (JIT enabled, AOT enabled)
JVM Command-line Options: -Xmn1100m -Xms1500m -Xmx1500m -Xaggressive -Xcompressedrefs -Xgcpolicy:gencon -XlockReservation -Xnoloa -XtlhPrefetch -Xlp
JVM Affinity: start /affinity [0xF, 0xF0, 0xF00,0xF000, 0xF0000, 0xF00000]
JVM Instances: 6
JVM Initial Heap (MB): 1500
JVM Maximum Heap (MB): 1500
JVM Address Bits: 64
Boot Firmware Version: P03
Management Firmware Version: 1.01
Workload Version: SSJ 1.2.6
Director Location: Controller
Other Software: None
Boot Firmware Settings
=
Management Firmware Settings
None
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Acer Incorporated
Model: Gateway GR160 F1
CPU Description: Intel Xeon E5504
Memory amount (GB): 4
Software
Operating System (OS): Windows Server 2008 x64, Enterprise Edition SP2
JVM Vendor: Oracle Corporation
JVM Version: Oracle JRockit(R) 6 P28.0.0 (build P28.0.0-29-114096-1.6.0_11-20090427-1759-windows-x86_64, compiled mode)
CCS Version: 1.2.4
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Electric International Pte. Ltd.
Model: WT210
Serial Number: 91H534921
Connectivity: RS232
Input Connection: Default
Calibration Institute: NML (National Measurement Laboratory, R.O.C.)
Accredited by: ETC, Taiwan
Calibration Label: 10-06-BAC-041-01
Date of Calibration: 10-Jun-2010
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.3.10-511c8daa
Setup Description: None
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: Watchport Virtual Port 5.0.0.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: None
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 259 27.4
90% 243 27.2
80% 229 27.2
70% 214 27.2
60% 198 27.2
50% 180 27.2
40% 164 27.2
30% 150 27.2
20% 139 27.2
10% 127 27.4
Active Idle 78.8 27.2
Line Standard Minimum Temperature (°C) Elevation (m)
220V / 60 Hz / 1 phase / 2 wires 27.2 132
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     908,719
Calibration 2     908,937
Calibration 3     909,547
ssj_ops@calibrated=909,242
100% 99.6% 909,242 905,850
90% 89.6% 818,318 815,054
80% 79.9% 727,394 726,302
70% 70.0% 636,469 636,771
60% 60.1% 545,545 546,532
50% 50.1% 454,621 455,907
40% 39.9% 363,697 362,751
30% 29.8% 272,773 271,362
20% 20.2% 181,848 183,438
10% 10.0% 90,924 90,769
Active Idle   0 0
Graph of results