Fujitsu Siemens Computers PRIMERGY RX100 S5 (Intel Xeon X3360) SPECpower_ssj2008 = 1,015 overall ssj_ops/watt
Test Sponsor: Fujitsu Siemens Computers SPEC License #: 22 Test Method: Single Node
Tested By: Fujitsu Siemens Computers Test Location: Paderborn, NRW, Germany Test Date: Sep 10, 2008
Hardware Availability: Sep-2008 Software Availability: Jul-2008 Publication: Sep 24, 2008
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 100.0% 185,487 115 1,610
90% 90.3% 167,508 112 1,490
80% 80.3% 148,858 109 1,366
70% 71.0% 131,637 105 1,252
60% 60.5% 112,098 99.9 1,123
50% 49.8% 92,304 93.5 987
40% 40.2% 74,481 87.3 853
30% 29.8% 55,183 80.0 690
20% 20.0% 37,095 74.3 499
10% 9.9% 18,436 68.6 269
Active Idle 0 63.0 0
∑ssj_ops / ∑power = 1,015
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: PRIMERGY RX100 S5 (Intel Xeon X3360)
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: Fujitsu Siemens Computers
Model: PRIMERGY RX100 S5 (Intel Xeon X3360)
Form Factor: --
CPU Name: Intel Xeon X3360
CPU Characteristics: 2.83 GHz, 2x6MB L2 cache, 1333MHz system bus
CPU Frequency (MHz): 2833
CPU(s) Enabled: 4 cores, 1 chip, 4 cores/chip
Hardware Threads: 4 (1 / core)
CPU(s) Orderable: 1 chip
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 12 MB I+D on chip per chip, 6 MB shared / 2 cores
Tertiary Cache: None
Other Cache: None
Memory Amount (GB): 4
# and size of DIMM: 2 x 2048 MB
Memory Details: PC2-6400E 2Rx8 (CAS 6-6-6)
Power Supply Quantity and Rating (W): 1 x 350
Power Supply Details: Delta Electronics, Inc DPS-350UB A
Disk Drive: 1 x Seagate (3.5", SATA, 160GB, 7.2krpm)
Disk Controller: Integrated SATA controller
# and type of Network Interface Cards (NICs) Installed: 2 x Broadcom NetXtreme Gigabit Ethernet (onboard)
NICs Enabled in Firmware / OS / Connected: 1/1/1
Network Speed (Mbit): 1000
Keyboard: KVM
Mouse: KVM
Monitor: KVM
Optical Drives: No
Other Hardware: None
Software
Power Management: Enabled (Server Balanced Processor Power and Performance)
Operating System (OS): Microsoft Windows Server 2003 R2 Enterprise x64 Edition
OS Version: Version 5.2.3790 Service Pack 1 Build 3790
Filesystem: NTFS
JVM Vendor: Oracle Corporation
JVM Version: Oracle JRockit(R) 6.0 P27.5.0 (build P27.5.0-5_o_CR371811_CR374296-100684-1.6.0_03-20080702-1651-windows-x86_64)
JVM Command-line Options: -Xms1650m -Xmx1650m -Xns1500m -XXaggressive -Xlargepages -Xgc:genpar -XXcallprofiling -XXgcthreads=2 -XXtlasize:min=4k,preferred=1024k -XXthroughputcompaction
JVM Affinity: start /affinity [0x3,0xC]
JVM Instances: 4
JVM Initial Heap (MB): 1650
JVM Maximum Heap (MB): 1650
JVM Address Bits: 64
Boot Firmware Version: --
Management Firmware Version: --
Workload Version: SSJ 1.1.3
Director Location: Controller
Other Software: None
Boot Firmware Settings
--
Management Firmware Settings
--
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Fujitsu Siemens Computers
Model: PRIMERGY RX100 S3
CPU Description: Pentium D 940
Memory amount (GB): 2
Software
Operating System (OS): Windows Server 2003 Enterprise Edition + SP1
JVM Vendor: BEA Systems, Inc.
JVM Version: BEA JRockit(R) R27.5.0 (build R27.5.0-110-94909-1.6.0_03-20080204-1558-windows-ia32)
CCS Version: 1.1.3
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: ZES Zimmer Electronic Systems GmbH
Model: LMG95
Serial Number: 11770806
Connectivity: RS-232
Input Connection: Default (20A)
Calibration Institute: PTB (Physikalisch Technische Bundesanstalt)
Accredited by: ZES
Calibration Label: 11770806.1f
Date of Calibration: 25-Jun-2008
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.3.2-e0c92e60
Setup Description: --
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: Watchport Virtual Port 4.50.0.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: --
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 115 20.6
90% 112 20.6
80% 109 20.6
70% 105 20.6
60% 99.9 20.6
50% 93.5 20.6
40% 87.3 20.6
30% 80.0 20.6
20% 74.3 20.6
10% 68.6 20.6
Active Idle 63.0 20.6
Line Standard Minimum Temperature (°C) Elevation (m)
230V / 50 Hz / 1 phase / 2 wires 20.6 117
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     181,961
Calibration 2     184,938
Calibration 3     185,911
ssj_ops@calibrated=185,425
100% 100.0% 185,425 185,487
90% 90.3% 166,882 167,508
80% 80.3% 148,340 148,858
70% 71.0% 129,797 131,637
60% 60.5% 111,255 112,098
50% 49.8% 92,712 92,304
40% 40.2% 74,170 74,481
30% 29.8% 55,627 55,183
20% 20.0% 37,085 37,095
10% 9.9% 18,542 18,436
Active Idle   0 0
Graph of results