- Power Technology:
-
This BIOS option allows to disable or define Power Management on server.
This can be one of the following: [Disable], [Energy Efficient] or [Custom].
Users should set this option as [Energy Efficient] for performing application benchmarking.
- Enforce POR:
-
Enable to enforce POR restriction for DDR4 frequency and voltage programming.
This can be one of the following: [Disabled] or [Enabled].
When memory modules are populated in two or more Dimm Per Channel, users should set this option as [Disabled] for manually selecting Memory Frequency.
- Memory Frequency:
-
When Enforce POR option is set as [Disabled], users can manually set Memory Frequency to maximum supported by the processor.
- COD Enable:
-
This Bios option is visible for Intel(R) E5-26xx v3 processors with 10+ cores.
Enabling this option reduce coherence traffic and cache-to-cache transfer latencies.
This can be one of the following: [Enable] or [Disable].
Users should set this option as [Enable] for performing application benchmarking.
- Fan Mode:
-
This feature allows manually selecting cooling mode.
This option can be set in the BMC.
Can be one of the following: [Standard Speed], [HeavyIO Speed], [Optimal Speed] or [Full Speed].
The first three options cause the fan speed is adapted to the current load on the server.
[Full Speed] option provides the best cooling regardless of the load on the server.
Users should set this option as [Full Speed] for performing application benchmarking.