SPEC SFS(R)2014_eda Result Oracle : Oracle ZFS Storage ZS7-2 Mid Range Four Tray Hybrid Storage System SPEC SFS2014_eda = 250 Job_Sets (Overall Response Time = 0.49 msec) =============================================================================== Performance =========== Business Average Metric Latency Job_Sets Job_Sets (Job_Sets) (msec) Ops/Sec MB/Sec ------------ ------------ ------------ ------------ 25 0.3 11250 252 50 0.3 22501 506 75 0.3 33751 760 100 0.3 45002 1013 125 0.5 56252 1266 150 0.4 67503 1519 175 0.6 78753 1771 200 0.6 89790 2019 225 1.0 101254 2276 250 0.6 112505 2529 =============================================================================== Product and Test Information ============================ +------------------------------------------------------------------+ |Oracle ZFS Storage ZS7-2 Mid Range Four Tray Hybrid Storage System| +------------------------------------------------------------------+ Tested by Oracle Hardware Available November 13, 2018 Software Available December 13, 2019 Date Tested January 2020 License Number 00073 Licensee Locations Redwood Shores, CA, USA The Oracle ZFS Storage ZS7-2 Mid-Range system is a cost-effective, unified storage system that is ideal for performance-intensive, dynamic workloads. This enterprise-class storage system offers both NAS and SAN capabilities with industry-leading Oracle Database integration, in a highly available, clustered configuration. The Oracle ZFS Storage ZS7-2 provides simplified configuration, management, and industry-leading storage Analytics. The performance-optimized platform leverages specialized read and write flash caching devices in the hybrid storage pool configuration, optimizing high-performance throughput and latency. The clustered Oracle ZFS Storage ZS7-2 Mid-Range system scales to 2.0TB Memory, includes 36 CPU cores per controller and 8 PB of disk storage. The Oracle ZFS Storage Appliance delivers excellent value with integrated data services for file and block-level protocols with connectivity over InfiniBand, 32GB FC, 40GbE, 25GbE, and 10GbE. Data can be compressed, deduplicated, encrypted, snapshot, and replicated. Data is protected by an advanced data integrity architecture and provides four RAID redundancy options to optimize different workloads. Solution Under Test Bill of Materials ===================================== Item No Qty Type Vendor Model/Name Description ---- ---- ---------- ---------- ---------- ----------------------------------- 1 2 Storage Oracle Oracle ZFS Oracle ZFS Storage ZS7-2, 2 x Controller Storage 18-Core 2.3GHz Xeon G-6140 CPU. 512 ZS7-2 Mid GB DDR4-2666 LRDIMM. 2 x 10TB SAS3 Range HGST boot drives. 2 16 Memory Oracle Oracle ZFS Oracle ZFS Storage ZS7-2, 16 x 64GB Storage DDR4-2666 LRDIMM. Memory is order ZS7-2 configurable, a total of 512GB was installed in each storage controller. 3 2 Storage Oracle Oracle 24 drive slot enclosure, SAS3 Drive Storage connected, 20 x 14TB Western Enclosure Drive Digital 7200 RPM - SAS-3 Disk Enclosure Drive, 2 x Western Digital 200GB - DE3-24C SAS-3 SSD, 2 x Western Digital 7.68TB - SAS-3 SSD. Dual PSU. 4 2 Storage Oracle Oracle 24 drive slot enclosure, SAS3 Drive Storage connected, 24 x 14TB Western Enclosure Drive Digital 7200 RPM - SAS-3 Disk Enclosure Drive. Dual PSU. DE3-24C 5 88 SAS3 HDD Oracle WDC W7214A 14TB Western Digital 7200 RPM - 520ORA014T SAS-3 Disk Drive. Drive selection is order configurable. A total of 88 x 14TB Western Digital 7200 RPM - SAS-3 Disk Drive drives were installed across all Oracle Storage Drive Enclosure DE3-24C. 6 4 SAS3 SSD Oracle WDC HPCAC2 Western Digital 200GB - SAS-3 Solid DH6ORA200G State Disk. Drive selection is order configurable, a total of 4 x Western Digital 200GB - SAS-3 Solid State Disk drives were installed across two Oracle Storage Drive Enclosure DE3-24C. These Drives are used for write accelerators. 7 4 SAS3 SSD Oracle WDC HPCAC2 Western Digital 7.68TB - SAS-3 DH2ORA7.6T Solid State Disk. Drive selection is order configurable, a total of 4 x Western Digital 7.68TB - SAS-3 Solid State Disk drives were installed across two Oracle Storage Drive Enclosure DE3-24C. These drives are used for ZFS L2 Adaptive Replacement Cache. 8 2 Client Oracle Oracle Oracle S7-2 Client Node, 2 x SPARC S7-2 S7 8-Core, 4.27GHz processors. 256GB RAM. 2 x (2 x 25GbE). Used for benchmark load generation. 9 2 OS Drive Oracle HGST H1018 HGST 1.2TB - 10000 RPM - SAS-3 Disk 12SFSUN1.2 Drive. 2 x 1.2TB - 10000 RPM - T SAS-3 Disk Drive, one for each Oracle S7-2 Client Node was installed for OS boot drive. 10 1 Switch Arista Arista Arista DCS-7060CX-32S, high- DCS- performance, low-latency 7060CX-32S 100/40/10/25/50 Gb/sec Ethernet switch. 11 8 Network Oracle Dual 10/25 Dual 10/25-Gigabit SFP28 Ethernet Interface -Gigabit HBA Card SFP28 Ethernet Configuration Diagrams ====================== 1) sfs2014-20200214-00069.config1.png (see SPEC SFS2014 results webpage) 2) sfs2014-20200214-00069.config2.png (see SPEC SFS2014 results webpage) Component Software ================== Item Name and No Component Type Version Description ---- ------------ ------------ ------------ ----------------------------------- 1 Oracle ZFS Storage 8.8.9 Oracle ZFS Storage OS Firmware. Storage Controller OS 2 Solaris Workload Solaris (11. Workload Client Operating System Client OS 4,5.11-11.4. 16.0.1.2.0) Hardware Configuration and Tuning - Physical ============================================ +----------------------------------------------------------------------+ | Oracle ZFS Storage ZS7-2 | +----------------------------------------------------------------------+ Parameter Name Value Description --------------- --------------- ---------------------------------------- MTU 9000 Network Jumbo Frames +----------------------------------------------------------------------+ | Oracle S7-2 Client Node | +----------------------------------------------------------------------+ Parameter Name Value Description --------------- --------------- ---------------------------------------- MTU 9000 Network Jumbo Frames Hardware Configuration and Tuning Notes --------------------------------------- The Solution Under Test has 25GbE Ethernet ports set to MTU 9000. S7-2 workload clients have power management software controls for SPARC processor power states. This control is set to administrative-authority equal "none" via the Solaris poweradm cli, which prevents CPU power throttling. Software Configuration and Tuning - Physical ============================================ +----------------------------------------------------------------------+ | Oracle S7-2 Client Nodes | +----------------------------------------------------------------------+ Parameter Name Value Description --------------- --------------- ---------------------------------------- vers 3 NFS mount option set to version 3 rsize, wsize 1048576 NFS mount option for the read and write buffer size. forcedirectio forcedirectio NFS mount option set to forcedirectio rpcmod:clnt_max 4 Increases the number of NFS client _conns connections from default of 1 to 4. Software Configuration and Tuning Notes --------------------------------------- Best practices settings for network and NFS client and the Oracle ZFS Storage using the 25GbE Ethernet for optimized performance includes setting the workload client NFS mounts of the Oracle to use forcedirectio, and read and write NFS buffer sizes to 1048576 bytes each. Service SLA Notes ----------------- None Storage and Filesystems ======================= Item Stable No Description Data Protection Storage Qty ---- ------------------------------------- ------------------ -------- ----- 1 88 x 14TB HDD Oracle ZFS Storage RAID-10 Yes 88 ZS7-2 Data Pool Drives 2 4 x 200GB SSD Oracle ZFS Storage None Yes 4 ZS7-2 Log Drives 3 Western Digital 7.68TB - SAS-3 Solid None Yes 4 State Disk ZS7-2 Read Cache Drives 4 10TB HGST Oracle ZFS Storage ZS7-2 OS Mirrored No 4 Drives 5 HGST 1.2TB - 10000 RPM - SAS-3 Disk None No 2 Drive S7-2 Client Node OS Drives Number of Filesystems 2 Total Capacity 467 TiB Filesystem Type ZFS Filesystem Creation Notes ------------------------- Two ZFS storage pools are created overall in the Solution Under Test (one storage pool per Oracle ZFS Storage ZS7-2 controller). Each storage pool is configured with 42 HDD drives, 2 write accelerator SSDs (log devices), 2 L2 Adaptive Replacement Cache SSDs (read cache), and 2 hot spare HDDs. The storage pools are configured via the administrative browser interface. Each storage controller assigns half the disk drives, log devices, and cache devices to be used. Next, the storage pools profiles are set to mirror (RAID-10) across the 42 data HDDs drives. The log profile and cache device profiles used are set to be striped. The log construct in each storage pool is the ZFS Intent Log (ZIL) for the pool. The cache construct is the ZFS L2 Adaptive Replacement Cache for the pool. Each storage pool is configured with one ZFS filesystem share. Since each controller is configured with one storage pool and each storage pool contains one ZFS filesystem share, the Solution Under Test has two ZFS filesystem shares (2 NFS shares). There are 2 internal mirrored system disk drives per Oracle ZFS Storage ZS7-2 controller and are used only for the controllers NAS operating system. These drives are exclusively used for the NAS Firmware and do not cache or store user data. The Oracle S7-2 workload clients mount the two NFS shares across four 25GbE networks such that each client accesses the two NFS shares via four network paths over eight NFS mounts (see Solution Under Test diagram). Storage and Filesystem Notes ---------------------------- All filesystems on both Oracle ZFS Storage ZS7-2 controllers are created with a setting of the Database Record Size of 16KB. The logbias setting is set to latency (the default value) for each filesystem. These standard settings are controlled through the Oracle ZFS Storage administration using the Administration browser or cli interfaces. Transport Configuration - Physical ================================== Item Number of No Transport Type Ports Used Notes ---- --------------- ---------- ----------------------------------------------- 1 25GbE Ethernet 8 Each Oracle ZFS Storage ZS7-2 Controller is networked via 4 x 25GbE Ethernet physical ports for data. 2 10GbE Ethernet 2 Each Oracle ZFS Storage ZS7-2 Controller uses 1 x 10GbE Ethernet physical port for NAS configuration and management. 3 25GbE Ethernet 8 Each Oracle S7-2 Client Node uses is networked via 4 x 25GbE Ethernet physical ports for data. 4 10GbE Ethernet 2 Each Oracle S7-2 Client Node uses 1 x 10GbE Ethernet physical port for configuration and management. Transport Configuration Notes ----------------------------- Each Oracle ZFS Storage controller uses 4 x 25 GbE Ethernet ports for a total of 8 x 25 GbE ports. In the event of a controller failure, IP address will be taken over by the surviving controller. All 25 GbE ports are set to MTU 9000. There is 1 x 10GbE port per controller assigned to the administration interface, this interface is only used to manage the controller and does not take part in data services in the Solution Under Test. Switches - Physical =================== Total Used Item Port Port No Switch Name Switch Type Count Count Notes ---- -------------------- --------------- ------ ----- ------------------------ 1 Arista DCS-7060CX- 100/40/10/25/50 128 16 All ports set for MTU 32S Gb/sec Ethernet 9000. Port count based Switch on 25GbE. Processing Elements - Physical ============================== Item No Qty Type Location Description Processing Function ---- ---- -------- -------------- ------------------------- ------------------- 1 4 CPU Oracle ZFS 2 x 18-Core 2.3GHz Xeon ZFS, TCP/IP, Storage ZS7-2 G-6140 CPU RAID/Storage Drivers, NFS 2 4 CPU Oracle S7-2 2 x SPARC V9 8-Core, TCP/IP, NFS Client Node 4.27GHz processors Processing Element Notes ------------------------ Each Oracle ZFS Storage ZS7-2 controller contains 2 physical processors, each with 18 processing cores. Oracle S7-2 client contains 2 physical processors, each with 8 processing cores. Memory - Physical ================= Size in Number of Description GiB Instances Nonvolatile Total GiB ------------------------- ---------- ---------- ------------ ------------ Memory in Oracle ZFS 477 2 V 954 Storage ZS7-2 Memory in Oracle S7-2 238 2 V 476 clients Grand Total Memory Gibibytes 1430 Memory Notes ------------ The Oracle ZFS Storage controllers' main memory is used for the ZFS Adaptive Replacement Cache (ARC is a read data cache), as well as operating system memory. Oracle S7-2 client memory is not used for storage or cache of the Oracle ZFS Storage ZS7-2 controllers, only for the client OS. Stable Storage ============== The Stable Storage requirement is guaranteed by the ZFS Intent Log (ZIL) which logs writes and other filesystem changing transactions to the stable storage of write flash accelerator SSDs or HDDs depending on the configuration. The Solution Under Test uses write flash accelerator SSDs. Writes and other filesystem changing transactions are not acknowledged until the data is written to stable storage. The Oracle ZFS Storage Appliance is an active-active cluster high availability system. In the event of a controller failure or power loss, each controller can take over for the other. Write flash accelerator SSDs and/or HDDs are located in shared disk shelves and can be accessed via the 4 backend SAS-3 channels from both controllers, the remaining active controller can complete any outstanding transactions using the ZIL. In the event of power loss to both controllers, the ZIL is used after power is restored to reinstate any writes and other filesystem changes. Solution Under Test Configuration Notes ======================================= The ZS7-2 component is the Oracle ZFS Storage ZS7-2 Mid Range in an active-active failover configuration. Other Solution Notes ==================== None. Dataflow ======== Please reference the Solution Under Test diagram. The 2 Oracle S7-2 workload clients are used for benchmark load generation. The Oracle S7-2 workload clients each mount 2 of the total 2 filesystems provided by the Oracle ZFS Storage cluster via NFSv3. One filesystem is shared from each Oracle ZFS Storage controller. Each of the two Oracle ZFS Storage controllers has 4 x 25GbE Ethernet ports for data service, all ports are assigned separate sub-networks. Each Oracle S7-2 workload client has 4 x 25GbE Ethernet ports, mounting each NFS share four times over four networks. This is diagramed in the Solution Under Test diagram. Other Notes =========== Oracle and ZFS are registered trademarks of Oracle Corporation in the U.S. and/or other countries. Intel and Xeon are registered trademarks of the Intel Corporation in the U.S. and/or other countries. Other Report Notes ================== The test sponsor attests, as of the date of publication, that CVE-2017-5754 (Meltdown), CVE-2017-5753 (Spectre variant 1), and CVE-2017-5715 (Spectre variant 2) patches are disabled in the system as tested and documented. There is support turning this protection off or on, it is disabled (off) for this Solution Under Test which is also the product default. These mitigations may be enabled through the standard administrative interface. There may be performance impacts when these patches are enabled. =============================================================================== Generated on Fri Mar 6 18:31:41 2020 by SpecReport Copyright (C) 2016-2020 Standard Performance Evaluation Corporation