Dell Inc. PowerEdge R7425 (AMD EPYC 7601 2.20 GHz) SPECpower_ssj2008 = 11,867 overall ssj_ops/watt
Test Sponsor: Dell Inc. SPEC License #: 55 Test Method: Single Node
Tested By: Dell Inc. Test Location: Round Rock, TX, USA Test Date: Feb 6, 2019
Hardware Availability: Dec-2018 Software Availability: Apr-2015 Publication: Feb 27, 2019
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.5% 4,374,583 268 16,337
90% 90.1% 3,960,919 253 15,658
80% 80.1% 3,522,945 237 14,889
70% 70.0% 3,077,532 218 14,105
60% 60.0% 2,637,850 200 13,193
50% 49.9% 2,195,801 184 11,943
40% 40.0% 1,759,864 170 10,330
30% 30.0% 1,319,844 157 8,400
20% 20.0% 879,965 144 6,112
10% 10.0% 439,459 128 3,425
Active Idle 0 77.5 0
∑ssj_ops / ∑power = 11,867
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: PowerEdge R7425
Hardware
Hardware Vendor: Dell Inc.
Model: PowerEdge R7425 (AMD EPYC 7601 2.20 GHz)
Form Factor: 2U
CPU Name: AMD EPYC 7601 2.20 GHz, Dell SKU [338-BNCG]
CPU Characteristics: 32 core, 2.20 GHz, 64 MB L3 Cache
CPU Frequency (MHz): 2200
CPU(s) Enabled: 64 cores, 2 chips, 32 cores/chip
Hardware Threads: 128 (2 / core)
CPU(s) Orderable: 1,2 chips
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 512 KB I+D on chip per core
Tertiary Cache: 64 MB I+D on chip per chip, 8 MB shared / 4 cores
Other Cache: None
Memory Amount (GB): 128
# and size of DIMM: 16 x 8 GB
Memory Details: 8GB 1Rx8 PC4-2666V; Dell SKU [370-ADNI], Slots A1-8,B1-8 populated.
Power Supply Quantity and Rating (W): 1 x 750
Power Supply Details: Dell SKU [450-ADWR]
Disk Drive: 1 x 240 GB SATA SSD, Dell SKU [400-AWHF]
Disk Controller: PERC H330 RAID Controller, Dell SKU [405-AANS]
# and type of Network Interface Cards (NICs) Installed: 1 x quad-port Broadcom 5720, Dell SKU [540-BBBW]
NICs Enabled in Firmware / OS / Connected: 4/4/1
Network Speed (Mbit): 1000
Keyboard: None
Mouse: None
Monitor: None
Optical Drives: No
Other Hardware: None
Software
Power Management: AMD Naples Balanced V3 (see SUT notes)
Operating System (OS): Microsoft Windows Server 2012 R2 Datacenter
OS Version: Version 6.3.9600.18969
Filesystem: NTFS
JVM Vendor: Oracle Corporation
JVM Version: Java HotSpot 64-Bit Server VM (build 24.80-b11, mixed mode), version 1.7.0_80-b15
JVM Command-line Options: -XX:InlineSmallCode=800 -XX:FreqInlineSize=2000 -XX:+UseLargePages -XX:+UseBiasedLocking -XX:ParallelGCThreads=1 -XX:+UseParallelOldGC -XX:+AggressiveOpts -XX:+UseAdaptiveSizePolicy -Xmx1024m -Xms1024m -Xmn900m
JVM Affinity: start /NODE [0,1,2,3,4,5,6,7] /AFFINITY [0x1,0x4,0x10,0x40,0x100,0x400,0x1000,0x4000]
JVM Instances: 64
JVM Initial Heap (MB): 1024
JVM Maximum Heap (MB): 1024
JVM Address Bits: 64
Boot Firmware Version: 1.6.7
Management Firmware Version: 3.21.25.22
Workload Version: SSJ 1.2.10
Director Location: Controller
Other Software: Microsoft Windows KB4480969 (see SUT notes)
Boot Firmware Settings
Management Firmware Settings
none
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Dell Inc
Model: PowerEdge R410
CPU Description: Intel Xeon E5620, 2.40 GHz
Memory amount (GB): 32.0
Software
Operating System (OS): Microsoft Windows Server 2008 R2 Enterprise Edition Service Pack 1
JVM Vendor: Oracle Corporation
JVM Version: Hotspot(TM) Client VM, version 1.8.0_121
CCS Version: 1.2.6
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Meters and Instruments Corporation
Model: WT210
Serial Number: 91KA21979
Connectivity: RS-232
Input Connection: Default
Metrology Institute: NIST
Accredited by: TesCom
Calibration Label: 66762
Date of Calibration: 27-Feb-2018
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.8.1-260d064e-20161220
Setup Description: Connected to power supply
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: 5.10.26.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 25 mm in front of SUT main airflow intake
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 268 20.9
90% 253 20.9
80% 237 20.9
70% 218 20.9
60% 200 20.9
50% 184 20.9
40% 170 20.8
30% 157 20.8
20% 144 20.8
10% 128 20.8
Active Idle 77.5 20.7
Line Standard Minimum Temperature (°C) Elevation (m)
208V / 60 Hz / 1 phase / 2 wires 20.7 255
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     4,399,471
Calibration 2     4,402,158
Calibration 3     4,392,917
ssj_ops@calibrated=4,397,538
100% 99.5% 4,397,538 4,374,583
90% 90.1% 3,957,784 3,960,919
80% 80.1% 3,518,030 3,522,945
70% 70.0% 3,078,276 3,077,532
60% 60.0% 2,638,523 2,637,850
50% 49.9% 2,198,769 2,195,801
40% 40.0% 1,759,015 1,759,864
30% 30.0% 1,319,261 1,319,844
20% 20.0% 879,508 879,965
10% 10.0% 439,754 439,459
Active Idle   0 0
Graph of results