Hewlett-Packard Company ProLiant ML110 G5 SPECpower_ssj2008 = 431 overall ssj_ops/watt
Test Sponsor: Intel Corp. SPEC License #: 3184 Test Method: Single Node
Tested By: Principled Technologies, Inc. Test Location: Durham, NC, USA Test Date: Jan 19, 2011
Hardware Availability: Feb-2008 Software Availability: May-2009 Publication: Feb 17, 2011
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.5% 98,472 135 731
90% 91.1% 90,167 133 679
80% 80.5% 79,692 129 618
70% 69.9% 69,212 125 554
60% 60.2% 59,625 121 494
50% 49.8% 49,267 116 426
40% 39.4% 38,981 110 354
30% 30.0% 29,715 105 282
20% 19.8% 19,617 101 195
10% 10.1% 9,995 97.0 103
Active Idle 0 93.7 0
∑ssj_ops / ∑power = 431
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: ProLiant ML110 G5
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: Hewlett-Packard Company
Model: ProLiant ML110 G5
Form Factor: Tower
CPU Name: Intel Xeon Processor 3075
CPU Characteristics: Dual-Core, 2.66 GHz, 4 MB L2 Cache, 1333 MHz system bus
CPU Frequency (MHz): 2660
CPU(s) Enabled: 2 cores, 1 chip, 2 cores/chip
Hardware Threads: 2 (1 / core)
CPU(s) Orderable: 1 chip
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 4 MB I+D on chip per chip
Tertiary Cache: None
Other Cache: None
Memory Amount (GB): 4
# and size of DIMM: 4 x 1024 MB
Memory Details: 1GB 2Rx8 PC2-6400E; all slots populated
Power Supply Quantity and Rating (W): 1 x 365
Power Supply Details: HP part #445067-001
Disk Drive: 2 x 160GB 7.2K RPM SATA RAID 1
Disk Controller: Integrated SATA controller with embedded RAID
# and type of Network Interface Cards (NICs) Installed: 1 x NC105i Gigabit Server Adapter
NICs Enabled in Firmware / OS / Connected: 1/1/1
Network Speed (Mbit): 1000
Keyboard: KVM
Mouse: KVM
Monitor: KVM
Optical Drives: Yes
Other Hardware: None
Software
Power Management: Enabled (see SUT Notes)
Operating System (OS): Microsoft Windows Server 2008, Enterprise x64 Edition
OS Version: SP2, Build 6002
Filesystem: NTFS
JVM Vendor: Oracle Corporation
JVM Version: Oracle JRockit(R)(build P28.0.0-29-114096-1.6.0_11-20090427-1759-windows-x86_64, compiled mode)
JVM Command-line Options: -Xms2800m -Xmx2800m -Xns2660m -XXaggressive -XXlargePages -XXthroughputCompaction -XXcallprofiling -XXlazyUnlocking -Xgc:genpar -XXgcthreads:2 -XXtlasize:min=12k,preferred=1024k
JVM Affinity: None
JVM Instances: 1
JVM Initial Heap (MB): 2800
JVM Maximum Heap (MB): 2800
JVM Address Bits: 64
Boot Firmware Version: 015 2009.10.09
Management Firmware Version: 03.05 09/15/2008
Workload Version: SSJ 1.2.6
Director Location: Controller
Other Software: None
Boot Firmware Settings
Hardware Prefetcher disabled in BIOS, Adjacent Cache Line Prefetch disabled in BIOS, Processor Power Management set to GV1/GV3 Only in BIOS
Management Firmware Settings
Default
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Super Micro Computer, Inc.
Model: Supermicro 6025W-NTR+V
CPU Description: Intel Xeon Processor E5472
Memory amount (GB): 16
Software
Operating System (OS): Microsoft Windows Server 2003, Enterprise Edition, Service Pack 2
JVM Vendor: BEA Systems, Inc.
JVM Version: BEA JRockit(R) (build R27.5.0-110_o-99226-1.5.0_14-20080528-1505-windows-ia32, compiled mode)
CCS Version: 1.2.4
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Electric International Pte. Ltd.
Model: WT210
Serial Number: 91GB45373
Connectivity: RS-232
Input Connection: Default
Calibration Institute: NIST
Accredited by: Davis Calibration
Calibration Label: 07-1673
Date of Calibration: 28-Jul-2010
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.4.0-7071d9e7
Setup Description: SUT Power Supply
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: 5.10.26.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 50 mm in front of SUT main air intake
Notes
Used USB-to-Serial converter, Model Sabrent SBT-USC1M (driver version 2.0.2.1), to connect power analyzer to the controller.

This benchmark result is intended to provide perspective on past power and/or performance using the historical hardware and/or software described on this result page.

The system as described on this result page was formerly generally available. At the time of this publication, it may not be shipping, and/or may not be supported, and/or may fail to meet other tests of General Availability described in the SPEC OSG Policy document, http://www.spec.org/osg/policy.html

This measured result may not be representative of the result that would be measured were this benchmark run with hardware and software available as of the publication date.

Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 135 22.4
90% 133 22.4
80% 129 22.4
70% 125 22.6
60% 121 22.3
50% 116 22.5
40% 110 22.3
30% 105 22.4
20% 101 22.3
10% 97.0 22.4
Active Idle 93.7 22.2
Line Standard Minimum Temperature (°C) Elevation (m)
120V / 60 Hz / 1 phase / 2 wires 22.2 132
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     99,632
Calibration 2     98,728
Calibration 3     99,281
ssj_ops@calibrated=99,005
100% 99.5% 99,005 98,472
90% 91.1% 89,104 90,167
80% 80.5% 79,204 79,692
70% 69.9% 69,303 69,212
60% 60.2% 59,403 59,625
50% 49.8% 49,502 49,267
40% 39.4% 39,602 38,981
30% 30.0% 29,701 29,715
20% 19.8% 19,801 19,617
10% 10.1% 9,900 9,995
Active Idle   0 0
Graph of results