Physics > Accelerator Physics
[Submitted on 29 Sep 2024]
Title:Error Determination in Sextupole Magnet Calibration and Alignment Measurements and Application to Horizontal Beam Size Calculations at the Cornell Electron-positron Storage Ring
View PDF HTML (experimental)Abstract:We report on measurements and modeling studies performed from 2021 to 2024 on the 76 sextupole magnets in the Cornell Electron-positron Storage Ring CESR. Beam-based, magnet-specific calibrations ($K_2$ value versus excitation current) were measured. It was found that the new calibrations differ from those previously in use by an average of 3.1% with an RMS spread of 12%. The uncertainties in the calibration correction factors average 1.7% with an RMS spread of 1.0%.
Sextupole alignment values relative to the reference orbit were measured by combining the measured beam position with the quadrupole and skew quadrupole terms caused by a sextupole strength change $\Delta K_2$. High accuracy was achieved by fitting to difference phase and coupling functions as $K_2$ was varied. The horizontal (vertical) average offset values were found to be -0.01 (0.03)~mm with RMS spread of 1.1 (0.9)~mm with some exceptionally large values of a few millimeters. Typical uncertainties are 0.01-0.02~mm.
The above measurements were motivated by the precision required in measuring horizontal beam size at each sextupole. A precision of 10\% for a \mbox{1-mm} beam size requires uncertainties of better than 0.1~$\mu$radian in the horizontal angle change produced in the sextupole for a typical strength change of \mbox{$\Delta K_2 \, L$ = 1 m$^{-2}$}, where $L$ is the length of the sextupole, as well as 10\% in the difference of the squared horizontal and vertical beam positions relative to the center of the sextupole. These precision values were achieved by the analysis of difference functions. However, a small source of horizontal angle change of unknown origin, independent of the sextupole strength, requires a sextupole strength range larger than now available to measure accurately the typical horizontal beam size at CESR.
Submission history
From: James Crittenden [view email][v1] Sun, 29 Sep 2024 14:59:02 UTC (4,263 KB)
Current browse context:
physics.acc-ph
Change to browse by:
References & Citations
Bibliographic and Citation Tools
Bibliographic Explorer (What is the Explorer?)
Litmaps (What is Litmaps?)
scite Smart Citations (What are Smart Citations?)
Code, Data and Media Associated with this Article
CatalyzeX Code Finder for Papers (What is CatalyzeX?)
DagsHub (What is DagsHub?)
Gotit.pub (What is GotitPub?)
Papers with Code (What is Papers with Code?)
ScienceCast (What is ScienceCast?)
Demos
Recommenders and Search Tools
Influence Flower (What are Influence Flowers?)
Connected Papers (What is Connected Papers?)
CORE Recommender (What is CORE?)
arXivLabs: experimental projects with community collaborators
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.