From: René Hafner TUK (hamburge_at_physik.uni-kl.de)
Date: Sat Aug 14 2021 - 10:22:37 CDT
Hi,
I am trying to use a distance like colvar to sample a surface with a
ligand using extended ABF.
In order to speed up the surface sampling process I turned the abf line
into a 3D one where I also sample the X and Y direction.
My colvar file roughly looks like:
colvar { name X; distanceZ ... } # Ligand distance from Membrane
Center in X direction
colvar { name Y; distanceZ ... } # Ligand distance from Membrane
Center in Y direction
colvar { name distanceFromMembrane} # Ligand local distance from
Membrane Surface (selfdefined)
abf { colvars X Y distanceFromMembrane; ... }
This means the third variable is not independent from/orthogonal to X
and Y but that shouldn't be and issue when using eABF.
Comparing 1D run and 3D run (averaged the 3D PMF over X,Y to get
PMF(distMembrane) )
* When I did 1D sampling ( only distanceFromMembrane) I obtained rougly
5.5kcal/mol as dG (difference from Minimum to a point far away from
Membrane)
* When I do *3D sampling* using "subtractAppliedForce *on*" *in all 3
colvars* I obtained dG ~ 4kcal/mol. (I used the term
"subtractAppliedForce" because I initially used metadynamics +eABF)
* When I do *3D sampling* using "subtractAppliedForce *off*" *in all 3
colvars* I obtained dG ~ 1-2kcal/mol.
*What is the correct way to sample non-independent variables with proper
guesses?*
(I expect the 3D to reconstruct the 1D sampling case when done correctly
and just help improving the sampling of the whole surface)
Kind regards
René
-- -- Dipl.-Phys. René Hafner TU Kaiserslautern Germany
This archive was generated by hypermail 2.1.6 : Fri Dec 31 2021 - 23:17:11 CST