obirwopt.exe
OBI 127M R/W Optical Option Diskette
IBM 127MB Magneto-Optical (MO) Disk Drive If the Operating System is OS/2 and there are only
FORMAT problems (read/write/copy is working), then Check the drivers installed
for the MO-drive (CONFIG.SYS) If OPTICAL.SYS is used, then a replacement
of OPTICAL.SYS can solve the problem
Next find the DRIVE-TYPE you are working with (FAT / SMALL or
230MB)
FAT - Drive
Right side Jumperblock (SCSI Address)
|
SMALL - Drive FUNCTION (DIP SWITCH ONLY SETUP) ( DIP S1 Switch)
FUNCTION |
|
|
|
|
|
|
|
|
DEFAULT Setup (Factory) |
|
|
|
|
|
|
|
|
Create unit Attention |
|
|
|
|
|
|
|
|
Disable Unit Attention |
|
|
|
|
|
|
|
|
Check SCSI Parity |
|
|
|
|
|
|
|
|
Ignore SCSI Parity |
|
|
|
|
|
|
|
|
Device Type X'07' |
|
|
|
|
|
|
|
|
Device Type X'00' |
|
|
|
|
|
|
|
|
No Spin Up on POR |
|
|
|
|
|
|
|
|
Auto Spin Up on POR |
|
|
|
|
|
|
|
|
No Security Mode (normal) |
|
|
|
|
|
|
|
|
C2 Security Mode |
|
|
|
|
|
|
|
|
Without Power Saving Mode |
|
|
|
|
|
|
|
|
With Power Saving Mode |
|
|
|
|
|
|
|
|
Reserved (MUST be OFF) |
|
|
|
|
|
|
|
|
Mode Page 1,2,3,4 Support (With Device TYPE X'00') |
|
|
|
|
|
|
|
|
FUNCTION (DIP SWITCH ONLY SETUP) ( DIP S2 SWITCH - SCSI
Address)
+------------------------------------+
|FUNCTION
|1 2 3 4|
|----------------------------+-------|
|SCSI Addr. 0
|0 0 0 -|
|----------------------------+-------|
|SCSI Addr. 1
|1 0 0 -|
|----------------------------+-------|
|SCSI Addr. 2
|0 1 0 -|
|----------------------------+-------|
|SCSI Addr. 3
|1 1 0 -|
|----------------------------+-------|
|SCSI Addr. 4
|0 0 1 -|
|----------------------------+-------|
|SCSI Addr. 5
|1 0 1 -|
|----------------------------+-------|
|SCSI Addr. 6
|0 1 1 -|
|----------------------------+-------|
|SCSI Addr. 7
|1 1 1 -|
|----------------------------+-------|
|Disable SCSI Terminator |- - - 1|
|----------------------------+-------|
|Enable SCSI Terminator |-
- - 0|
+------------------------------------+
FUNCTION (DIP SWITCH and CONNECTOR SETUP)
0 = DIP SW -Off
1 = DIP SW -ON
P =CONNECTOR Open
S = CONNECTOR Short to Ground (CON C1-1)
H = HIGH (Output)
L = LOW (Output)
+----------------------------------------------------------------+
|FUNCTION
| CON C1 | DIP S1| DIP S2| CON C2|
|----------------------------+-----------+-------+-------+-------|
|Create Unit Attention
|- - - - - P|0 - 0 0|- - - -|S - S -|
|----------------------------+-----------+-------+-------+-------|
|Disable Unit Attention |-
- - - - P|0 - 0 0|- - - -|P - S -|
|----------------------------+-----------+-------+-------+-------|
|Device Type X'07'
|- - - - - P|0 - 0 0|- - - -|- S S -|
|----------------------------+-----------+-------+-------+-------|
|Device Type X'00'
|- - - - - P|0 - 0 0|- - - -|- S S -|
|----------------------------+-----------+-------+-------+-------|
|Mode Page 20 Support
|- - - - - S|1 1 1 -|- - - -|P P P -|
|----------------------------+-----------+-------+-------+-------|
|SCSI ADDRESS 0
|- P P P - -|- - - -|0 0 0 -|- - - -|
|----------------------------+-----------+-------+-------+-------|
|SCSI ADDRESS 1
|- S P P - -|- - - -|0 0 0 -|- - - -|
|----------------------------+-----------+-------+-------+-------|
|SCSI ADDRESS 2
|- P S P - -|- - - -|0 0 0 -|- - - -|
|----------------------------+-----------+-------+-------+-------|
|SCSI ADDRESS 3
|- S S P - -|- - - -|0 0 0 -|- - - -|
|----------------------------+-----------+-------+-------+-------|
|SCSI ADDRESS 4
|- P P S - -|- - - -|0 0 0 -|- - - -|
|----------------------------+-----------+-------+-------+-------|
|SCSI ADDRESS 5
|- S P S - -|- - - -|0 0 0 -|- - - -|
|----------------------------+-----------+-------+-------+-------|
|SCSI ADDRESS 6
|- P S S - -|- - - -|0 0 0 -|- - - -|
|----------------------------+-----------+-------+-------+-------|
|SCSI ADDRESS 7
|- S S S - -|- - - -|0 0 0 -|- - - -|
|----------------------------+-----------+-------+-------+-------|
|Disable SCSI Terminator |- - - -
- -|- - - -|- - - 0|- - - S|
|----------------------------+-----------+-------+-------+-------|
|Enable SCSI Terminator |-
- - - - -|- - - -|- - - 0|- - - P|
|----------------------------+-----------+-------+-------+-------|
|----------------------------+-----------+-------+-------+-------|
|Normal Mode (Output)
|- - - - H -|- - - -|- - - -|- - - -|
|----------------------------+-----------+-------+-------+-------|
|Power Saving Mode (Output) |- - - - L -|- - - -|-
- - -|- - - -|
|----------------------------+-----------+-------+-------+-------|
|----------------------------+-----------+-------+-------+-------|
|Ground
(Output) |L - - - - -|- - - -|- - - -|- - - -|
+----------------------------------------------------------------+
127MB MO-Drive DOS OS/2 CONFIG.SYS examples
CONFIG.SYS example (FAT-drive used with DOS)
DEVICE=C:\IBMRWOPT.SYS
/U
CONFIG.SYS example (SMALL-drive used withDOS)
DEVICE=C:\OPTIMO\OPTIMO.EXE
in an available OPTIMO.CFG file you will
see
rem
timeout 0
adapter
IBM # =0
drive
IBM3125 cid=2 lun =0
CONFIG.SYS example (FAT-drive used with OS/2)
DEVICE=C:\OS2\SCSI.SYS
/N :4
DEVICE=C:\OS2\OPTICAL.SYS
/N:4 /U
(some newer OPTICAL.SYS driver support /T:xx parameters (POWER-save
option, after xx minutes.))
NOTE: (OPTICAL.SYS parameter)
/L for LONG FORMAT
/N:x Number of SCSI devices in the computer
/Q Quiet mode (no message during OS/2
startup)
/U Unattended mode (OS/2 assign the
drive letter)
CONFIG.SYS example (SMALL-drive used with OS/2 V-2.0 or higher)
If you are running OS/2 V-2.1 or below, you MUST replace the existing FORMAT.COM file in the C:\OS2 directory, with the FORMAT.COM shipped with the OPTION. (Optical Disk Driver For OS/2 diskette) (rename the original FORMAT.COM, do not delete !)
BASEDEV = IBM2SCSI.ADD
/LED (only on PS/2 systems used)
BASEDEV = OS2SCSI.DMD
DEVICE=C:\OS2\MO.SYS
/D1
°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°
IBM 230MB Magneto-Optical (MO) Disk Drives (Internal and External)
Product Description The 230MB MO-drive meets the Small Computer System Interface-2 (SCSI-2) standards set by ANSI. This drive reads and writes both 128MB and 230MB optical media. The SCSI supports data transfer rates up to 5 megabytes / sec.
System Type Settings
Thet following table indicates some possible combinations of the customization
switch settings for several manufacturer computers.
.... for 230MB INTERNAL Drives
System Type Position 1
Position 3
------------------------------------------
IBM PC
ON ON
Apple Macintosh OFF
ON
Sun
OFF OFF
DEC
OFF OFF
.... for 230MB EXTERNAL Drives
System Type Position 3
----------------------------
IBM PC
ON
Apple Macintosh ON
Sun
OFF
DEC
OFF
Termination SETUP (230MB - Internal Drive)
+---------------------------------------------------------------------+
|SCSI-ID
|INTERNAL |Apple / Sun / DEC| IBM PC
|
|
| DIP-SW | EXTERNAL - DRIVE | EXTERNAL - DRIVE |
|
|4 3 2 1 | Rotary Switch | Rotary Switch
|
|---------------------+---------+------------------+------------------|
|SCSI Addr. 7 |-
1 1 1 | 7
| F
|
|---------------------+---------+------------------+------------------|
|SCSI Addr. 6 |-
1 1 0 | 6
| E
|
|---------------------+---------+------------------+------------------|
|SCSI Addr. 5 |-
1 0 1 | 5
| D
|
|---------------------+---------+------------------+------------------|
|SCSI Addr. 4 |-
1 0 0 | 4
| C
|
|---------------------+---------+------------------+------------------|
|SCSI Addr. 3 |-
0 1 1 | 3
| B
|
|---------------------+---------+------------------+------------------|
|SCSI Addr. 2 |-
0 1 0 | 2
| A
|
|---------------------+---------+------------------+------------------|
|SCSI Addr. 1 |-
0 0 1 | 1
| 9
|
|---------------------+---------+------------------+------------------|
|SCSI Addr. 0 |-
0 0 0 | 0
| 8
|
|---------------------+---------+------------------+------------------|
|Termination DISABLE |1 - - - |No Terminator
|No Terminator |
|
| |conn.
|conn.
|
|---------------------+---------+------------------+------------------|
|Termination ENABLE |0 - - - |Terminator
|Terminator |
|
| |connected
|connected |
+---------------------------------------------------------------------+
Customization Switch Settings (230MB - Internal Drive)
If you are not familiar with the customization
switch, use the default settings (marked with (* )
Write cache is used to improve performance
of the Optical Drive by returning a write complete status when the
data to be written has been loaded into the buffer memory of the
Optical Drive. There is a small risk of the data being lost due to a
power loss or drive failure with write caching enabled.
The user should choose either
performance improvement (write cache enabled) or fail-save data integrity
(write cache disabled)
Position 4 defines how the Optical Drive
configures itself after it is turned on or using a SCSI Reset situation.
This setting may be over-ridden by the write caching option chosen in the
device driver. See the README.TXT files that come on the device driver
diskettes for OS/2 and DOS for details.
+--------------------------------------------------------------------------------+
|SW-Pos|Setting|Description (INTERNAL drive)
|
|------+-------+-----------------------------------------------------------------|
| 1 |ON (* |Enable unit attention on POR/SCSI
reset
|
|------+-------+-----------------------------------------------------------------|
| 1 |OFF |With Position 3 ON:
|
| |
|Disable Unit Attention on POR/SCSI reset (for Apple attachment)
|
| |
|With Position 3 OFF:
|
| |
|Mode Page 1,2,3,4 support (for DEC/SUN attachment)
|
|------+-------+-----------------------------------------------------------------|
| 2 |ON (* |Check SCSI parity
|
|------+-------+-----------------------------------------------------------------|
| 2 |OFF |Ignore SCSI parity
|
|------+-------+-----------------------------------------------------------------|
| 3 |ON (* |Device type inquiry data is
hex 07 (optical disk drive)
|
|------+-------+-----------------------------------------------------------------|
| 3 |OFF |Device type inquiry
data is hex 00 (hard disk drive)
|
|------+-------+-----------------------------------------------------------------|
| 4 |ON (* |Write cache disabled after
POR/SCSI reset
|
|------+-------+-----------------------------------------------------------------|
| 4 |OFF |Write cache enabled
after POR/SCSI reset
|
| |
|(NOTE: with pos 1,2,3,4 set to ON,ON,OFF and OFF
|
| |
|respectively, write cache is disabled after Reset.)
|
|------+-------+-----------------------------------------------------------------|
| 5 |ON |No spin-up on
POR
|
|------+-------+-----------------------------------------------------------------|
| 5 |OFF (* |Spin-up automatically on POR
|
|------+-------+-----------------------------------------------------------------|
| 6 |ON (* |Normal Mode
|
|------+-------+-----------------------------------------------------------------|
| 6 |OFF |C2 Security Mode
|
|------+-------+-----------------------------------------------------------------|
| 7 |ON |Default value
of time interval hex FF (Do not enter power-down |
| |
|mode.)
|
|------+-------+-----------------------------------------------------------------|
| 7 |OFF (* |Default value of time interval hex
05 (Enter power-down mode |
| |
|after 5 minutes.)
|
|------+-------+-----------------------------------------------------------------|
| 8 |OFF (* |Reserved (must remain OFF)
|
|------+-------+-----------------------------------------------------------------|
+--------------------------------------------------------------------------------+
Customization Switch Settings ( 230MB - External Drive)
+--------------------------------------------------------------------------------+
|SW-Pos|Setting|Description (EXTERNAL drive)
|
|------+-------+-----------------------------------------------------------------|
| 1 |OFF (* |Must remain in the OFF position
for the External Drive to |
| |
|function properly
|
|------+-------+-----------------------------------------------------------------|
| 2 |ON (* |Check SCSI parity
|
|------+-------+-----------------------------------------------------------------|
| 2 |OFF |Ignore SCSI parity
|
|------+-------+-----------------------------------------------------------------|
| 3 |ON (* |Device type in inquiry data
is hex 07 (optical disk drive) |
|------+-------+-----------------------------------------------------------------|
| 3 |OFF |Device type in inquiry
data is hex 00 (hard disk drive)
|
|------+-------+-----------------------------------------------------------------|
| 4 |ON (* |Write cache disabled after
POR/SCSI reset
|
|------+-------+-----------------------------------------------------------------|
| 4 |OFF |Write cache enabled
after POR/SCSI reset
|
| |
|(NOTE: with pos 1,2,3,4 set to ON,ON,OFF and OFF
|
| |
|respectively, write cache is disabled after Reset.)
|
|------+-------+-----------------------------------------------------------------|
| 5 |ON |No spin-up on
POR
|
|------+-------+-----------------------------------------------------------------|
| 5 |OFF (* |Spin-up automatically on POR
|
|------+-------+-----------------------------------------------------------------|
| 6 |ON (* |Normal Mode
|
|------+-------+-----------------------------------------------------------------|
| 6 |OFF |C2 Security Mode
|
|------+-------+-----------------------------------------------------------------|
| 7 |ON |Default value
of time interval hex FF (Do not enter power-down |
| |
|mode.)
|
|------+-------+-----------------------------------------------------------------|
| 7 |OFF (* |Default value of time interval hex
05 (Enter power-down mode |
| |
|after 5 minutes.)
|
|------+-------+-----------------------------------------------------------------|
| 8 |OFF (* |Reserved (must remain OFF)
|
+--------------------------------------------------------------------------------+