  1. Whats a pedestal? | Information by Electrical Professionals for ...

    Dec 20, 2008 · The utility company trenches to the pedestal, they lay their wires in the trench, up into the pedestal and then make up their terminations. What's nice with this setup is that we …

  2. Electrical pedestal | Information by Electrical Professionals for ...

    Dec 10, 2017 · If pedestal would only have receptacle(s) in it - then worst case it is a structure supplied by a branch circuit. Supply it with a service or a feeder and it should need a …

  3. Help me identify a mobile home pedestal | Information by …

    Jan 18, 2019 · One obvious need is a pedestal that is between the service connection on the street (which is also a pedestal with the meter and main breaker) and the panel on the actual …

  4. Wavepro Seat Pedestal - Michigan Sportsman Forum

    Mar 27, 2023 · The Wave Pro pedestal is built on a FOX shock which is one of the kings of off-road shock absorbers. They'll likely last a lifetime and will be easily rebuilt if necessary. After …

  5. Pedestal Service | Information by Electrical Professionals for ...

    Sep 2, 2005 · Re: Pedestal Service Q1) Since pedestal has main disconnect, is exterior panel at house considered SUB which requires isolation on EGC & Nuetral and pedestal considered …

  6. Pedestal service grounding | Information by Electrical Professionals ...

    Nov 1, 2005 · Re: Pedestal service grounding I have a three wire triplex (Bare is the neutral)feeding the sub-panel...The sub-panel (Main lug) is grounded with a ground rod. From …

  7. Boat Seat Wave Dampening Pedestal - Michigan Sportsman Forum

    Mar 21, 2019 · What is everyone running for pedestal upgrades to help with the ride? Looking for any suggestions / recommendations / ideas. I did run across this Springfield Ez-Ride Wave …

  8. RV pedestals and the Tap Rule - Mike Holt's Forum

    Jun 7, 2020 · The breakers inside the pedestal are fed from a single phase 240V, 125A panel bus. The bus is fed by #1 copper tap conductors that are, in turn, fed by a set of lugs which …

  9. pedestal combination meter and main | Information by Electrical ...

    Feb 3, 2005 · Re: pedestal combination meter and main Adding a breaker to the pedestal in no way changes the method of installation, or negatively affects safety. It changes which codes …

  10. From service pedestal to house...3 or 4 wire? | Information by ...

    Oct 8, 2013 · IMO, Yes a 4-wire system is requierd based on 250.32(D) of 2008 edition. The service pedestal qualifies as a structure and any wiring from that point of main disocnnect …